Datasheet

Data Sheet MAT01
SPECIFICATIONS
ELECTRICAL CHARACTERISTICS
V
CB
= 15 V, I
C
= 10 µA, T
A
= 25°C, unless otherwise noted.
Table 1.
Parameter Symbol Test Conditions/Comments
MAT01AH MAT01GH
Unit Min Typ Max Min Typ Min
VOLTAGE
Breakdown Voltage BV
CEO
I
C
= 100 µA 45 45 V
Offset Voltage V
OS
0.04 0.1 0.10 0.5 mV
Offset Voltage Stability
First Month
1
V
OS
/Time 2.0 2.0 µV/Mo
Long Term
2
0.2 0.2 µV/Mo
CURRENT
Offset Current I
OS
0.1 0.6 0.2 3.2 nA
Bias Current I
B
13 20 18 40 nA
Current Gain h
FE
I
C
= 10 nA 590 430
I
C
= 10 µA 500 770 250 560
I
C
= 10 mA
840
610
Current Gain Match
∆h
FE
I
C
= 10 µA
0.7
1.0
8.0
%
100 nA ≤ I
C
≤ 10 mA 0.8 1.2 %
NOISE
Low Frequency Noise Voltage e
n
p-p 0.1 Hz to 10 Hz
3
0.23 0.4 0.23 0.4 µV p-p
Broadband Noise Voltage e
n
rms 1 Hz to 10 kHz 0.60 0.60 µV rms
Noise Voltage Density e
n
f
O
= 10 Hz
3
7.0 9.0 7.0 9.0 nV/√Hz
f
O
= 100 Hz
3
6.1 7.6 6.1 7.6 nV/√Hz
f
O
= 1000 Hz
3
6.0 7.5 6.0 7.5 nV/√Hz
OFFSET VOLTAGE/CURRENT
Offset Voltage Change ∆V
OS
/∆V
CB
0 ≤ V
CB
30 V 0.5 3.0 0.8 8.0 µV/V
Offset Current Change ∆I
OS
/∆V
CB
0 ≤ V
CB
30 V 2 15 3 70 pA/V
LEAKAGE
Collector to Base Leakage Current I
CBO
V
CB
= 30 V, I
E
= 0
4
15 50 25 200 pA
Collector to Emitter Leakage Current I
CES
V
CE
= 30 V, V
BE
= 0
4, 5
50 200 90 400 pA
Collector to Collector Leakage Current I
CC
V
CC
= 30 V
5
20 200 30 400 pA
SATURATION
Collector Saturation Voltage V
CE(SAT)
I
B
= 0.1 mA, I
C
= 1 mA 0.12 0.20 0.12 0.25 V
I
B
= 1 mA, I
C
= 10 mA
0.8
0.8
V
GAIN BANDWIDTH PRODUCT f
T
V
CE
= 10 V, I
C
= 10 mA 450 450 MHz
CAPACITANCE
Output Capacitance C
OB
V
CB
= 15 V, I
E
= 0 2.8 2.8 pF
Collector to Collector Capacitance C
CC
V
CC
= 0 8.5 8.5 pF
1
Exclude first hour of operation to allow for stabilization.
2
Parameter describes long-term average drift after first month of operation.
3
Sample tested.
4
The collector to base (I
CBO
) and collector to emitter (I
CES
) leakage currents can be reduced by a factor of 2 to 10 times by connecting the substrate (package) to a
potential that is lower than either collector voltage.
5
I
CC
and I
CES
are guaranteed by measurement of I
CBO
.
Rev. D | Page 3 of 12