Datasheet
AD5750/AD5750-1
Rev. C | Page 10 of 36
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Transient currents of up to 100 mA do not cause SCR latch-up.
Table 4. Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Parameter Rating
AVDD to GND −0.3 V to +30 V
AVSS to GND +0.3 V to −28 V
AVDD to AVSS −0.3 V to +58 V
DVCC to GND −0.3 V to +7 V
VSENSE+ to GND AV
SS
to AV
DD
VSENSE− to GND ±5.0 V
Digital Inputs to GND
−0.3 V to DV
CC
+ 0.3 V or 7 V
(whichever is less)
Digital Outputs to GND
−0.3 V to DV
CC
+ 0.3 V or 7 V
(whichever is less)
VREF to GND −0.3 V to +7 V
VIN to GND −0.3 V to +7 V
VOUT, IOUT to GND AV
SS
to AV
DD
Operating Temperature Range, −40°C to +105°C
Industrial
Storage Temperature Range −65°C to +150°C
Junction Temperature (T
J
max) 125°C
32-Lead LFCSP Package
θ
JA
Thermal Impedance 28°C/W
Lead Temperature JEDEC industry standard
Soldering J-STD-020
ESD (Human Body Model) 3 kV
ESD CAUTION