Datasheet

AD5560 Data Sheet
Rev. D | Page 12 of 68
Parameter Min Typ Max Unit Test Conditions/Comments
Power Supply Sensitivity
1
DC to 1 kHz.
ΔForced Voltage/ΔAV
DD
−65 dB −30 dB at 100 kHz.
ΔForced Voltage/ΔAV
SS
−65 dB 25 dB at 100 kHz.
ΔForced Voltage/ΔHCAV
DD
x −90 dB −60 dB at 100 kHz.
ΔForced Voltage/ΔHCAV
SS
x −90 dB −62 dB at 100 kHz.
ΔMeasured Current/ΔAV
DD
−50 dB −25 dB at 100 kHz.
ΔMeasured Current/ΔAV
SS
−43 dB 20 dB at 100 kHz.
ΔMeasured Current/ΔHCAV
DD
x −90 dB −60 dB at 100 kHz.
ΔMeasured Current/ΔHCAV
SS
x −90 dB 60 dB at 100 kHz.
ΔMeasured Voltage/ΔAV
DD
−65 dB −30 dB at 100 kHz.
ΔMeasured Voltage/ΔAV
SS
−65 dB −25 dB at 100 kHz.
ΔMeasured Voltage/ΔHCAV
DD
x −90 dB −60 dB at 100 kHz.
ΔMeasured Voltage/ΔHCAV
SS
x −90 dB −65 dB at 100 kHz.
ΔForced Voltage/ΔDV
CC
−80 dB −46 dB at 100 kHz.
ΔMeasured Current/ΔDV
CC
−80 dB −36 dB at 100 kHz.
ΔMeasured Voltage/ΔDV
CC
−80 dB −46 dB at 100 kHz.
1
Guaranteed by design and characterization, not subject to production test.
2
Programmable clamps must be enabled if taking advantage of reduced headroom/footroom.
3
Clamps disabled.
4
Not including internal pull-up current between AVDD/AVSS and HCAVDDx/HCAVSSx pins.