Datasheet

AD5522 Data Sheet
Rev. E | Page 8 of 64
Parameter Min Typ
1
Max Unit Test Conditions/Comments
CURRENT CLAMPS
Clamp Accuracy
Programmed
clamp value
Programmed
clamp value ± 10
% FSC
MI gain = 10, clamp current scales with
selected range
Programmed
clamp value
Programmed
clamp value ± 20
% FSC MI gain = 5, clamp current scales with selected range
CLL to CLH
5
% of
I
RANGE
CLL < CLH and minimum setting apart, MI gain = 10
10
% of
I
RANGE
CLL < CLH and minimum setting apart, MI gain = 5
Recovery Time
2
0.5 1.5 μs
Activation Time
2
1.5 3 μs
FOHx, EXTFOHx, EXTMEASILx,
EXTMEASIHx, CFFx PINS
Pin Capacitance
10 pF
Leakage Current −3 +3 nA
Individual pin on or off switch leakage, measured with
±11 V stress applied to pin, channel enabled, but tristate
Leakage Current Tempco
2
±0.01 nA/°C
3
pF
−3
+3
nA
Measured with ±11 V stress applied to pin,
channel enabled, but tristate
Leakage Current Tempco
±0.01 nA/°C
SYS_SENSE PIN SYS_SENSE connected, force amplifier inhibited
Pin Capacitance
2
3 pF
Switch Impedance 1 1.3
Leakage Current −3 +3 nA Measured with ±11 V stress applied to pin, switch off
Leakage Current Tempco
2
±0.01 nA/°C
SYS_FORCE PIN SYS_FORCE connected, force amplifier inhibited
Pin Capacitance
2
6 pF
Switch Impedance 60 80 Ω
Leakage Current −3 +3 nA Measured with ±11 V stress applied to pin, switch off
Leakage Current Tempco
2
±0.01 nA/°C
COMBINED LEAKAGE AT DUT
Includes FOHx, MEASVHx, SYS_SENSE, SYS_FORCE,
EXTMEASILx, EXTMEASIHx, EXTFOHx, and CFFx;
calculation of all the individual leakage contributors
Leakage Current −15 +15 nA T
J
= 25°C to 70°C
−25 +25 nA T
J
= 25°C to 90°C
Leakage Current Tempco
2
±0.1 nA/°C
Voltage Range −500 +500 mV
−30
+30
nA
MEASOUTx PIN With respect to AGND
Output Voltage Span 22.5 V Software programmable output range
Output Impedance 60 80 Ω
Output Leakage Current −3 +3 nA With SW12 off
Output Capacitance
2
15 pF
Maximum Load Capacitance
2
0.5 μF
Output Current Drive
2
2 mA
Short-Circuit Current −10 +10 mA
2
V/μs
150
320
ns
Closing SW12, measured from
BUSY
rising edge
400
1100
ns
Opening SW12, measured from
BUSY
rising edge
MI to MV Switching Time
200 ns
Measured from
BUSY
rising edge; does not include
slewing or settling