Datasheet

Evaluation Board User Guide UG-094
Rev. A | Page 5 of 12
08878-005
Figure 5. AD527xSDZ Evaluation Board Main Window
SOFTWARE OPERATION
The AD527xSDZ evaluation board main window has three
sections: RDAC, CONTROL REGISTER, and 50-TP.
These sections do the following:
The RDAC section displays the data that is read from the
RDAC, and it is shown in the resistor figure. When users
write to the part, this value is updated.
The CONTROL REGISTER section allows access to the
control register, enabling or disabling the resistor performance
(R-PERFORMANCE) mode, RDAC write protection, and
the 50-TP memory.
The 50-TP section shows the LAST FUSE PROGRAMMED,
and the data blew into the fuses.
The AD527xSDZ evaluation board main window also includes
four buttons that do the following:
POWERDOWN powers down the part. Note that when
users click the POWERDOWN button, the text of the
button changes to POWERUP. The button automatically
toggles the power-up/power-down bit when it is pressed.
SOFT RESET sends a reset by software.
HARD RESET sends a reset by hardware. Note that this is
only available for the EVAL-AD5272SDZ.
BLOW FUSE blows the actual RDAC register data in the
50-TP memory. When it is successful, the message box in
Figure 6 appears, and when it is unsuccessful, the message
box in Figure 7 appears. Before clicking BLOW FUSE,
remember to enable the 50-TP memory.
08878-006
Figure 6. Blow Fuse Successfully
08878-007
Figure 7. Blow Fuse Unsuccessful
EXIT closes the program. Note that this does not reset the part.