SOFTWARE OPERATION
The main window of the EVAL -AD5247DBZ software is divided
into the following sections: RDAC and MANUAL DATA.
RDAC
WRITE can be used to update the RDAC registers by entering a
desirable value into the text box and clicking WRITE. When
WRITE is clicked, a write/read operation is performed, and the
value displayed in this section is updated with the actual RDAC
register value. This function can be used to verify whether the
write operation was completed successfully.
MANUAL WRITE
SEND DATA is a customized I
2
C data-word can be sent by
manually switching the scroll bars from 0 to 1 or from 1 to 0
as desired and then clicking SEND DATA.
In addition, the scroll bars are updated on each write transfer,
showing the command sent to the part.
EXIT closes the program.