Datasheet
Table Of Contents
- FEATURES
- APPLICATIONS
- GENERAL DESCRIPTION
- REVISION HISTORY
- INTRODUCTION
- FUNCTIONAL BLOCK DIAGRAM
- SPECIFICATIONS
- ABSOLUTE MAXIMUM RATINGS
- PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
- ANALOG FRONT END
- ANALOG INPUT MUXING
- MANUAL INPUT MUXING
- XTAL CLOCK INPUT PIN FUNCTIONALITY
- 28.63636 MHz CRYSTAL OPERATION
- ANTIALIASING FILTERS
- SCART AND FAST BLANKING
- FAST BLANK CONTROL
- FB_MODE [1:0], Address 0xED [1:0]
- Static Mux Selection Control
- Alpha Blend Coefficient
- Fast Blank Edge Shaping
- Contrast Reduction
- Contrast Reduction Enable
- Contrast Mode
- Fast Blank and Contrast Reduction Programmable Thresholds
- FB_INV, Address 0xED [3], Write Only
- Readback of FB Pin Status
- FB Timing
- Alignment of FB Signal
- Color Space Converter Manual Adjust
- GLOBAL CONTROL REGISTERS
- STANDARD DEFINITION PROCESSOR (SDP)
- SD LUMA PATH
- SD CHROMA PATH
- SYNC PROCESSING
- VBI DATA RECOVERY
- GENERAL SETUP
- Video Standard Selection
- Autodetection of SD Modes
- VID_SEL [3:0], Address 0x00 [7:4]
- AD_SEC525_EN, SECAM 525 Autodetect Enable, Address 0x07 [7]
- AD_SECAM_EN, SECAM Autodetect Enable, Address 0x07 [6]
- AD_N443_EN, NTSC 443 Autodetect Enable, Address 0x07 [5]
- AD_P60_EN, PAL 60 Autodetect Enable, Address 0x07 [4]
- AD_PALN_EN, PAL N Autodetect Enable, Address 0x07 [3]
- AD_PALM_EN, PAL M Autodetect Enable, Address 0x07 [2]
- AD_NTSC_EN, NTSC Autodetect Enable, Address 0x07 [1]
- AD_PAL_EN, PAL (B/G/I/H) Autodetect Enable, Address 0x07 [0]
- Subcarrier Frequency Lock Inversion
- Lock-Related Controls
- VS_COAST_MODE [1:0], Address 0xF9 [3:2]
- ST_NOISE_VLD, Sync Tip Noise Measurement Valid, Address 0xDE [3], Read Only
- ST_NOISE [10:0], Sync Tip Noise Measurement, Addresses 0xDE [2:0], 0xDF [7:0]
- COLOR CONTROLS
- CON [7:0], Contrast Adjust, Address 0x08 [7:0]
- SD_SAT_CB [7:0], SD Saturation Cb Channel, Address 0xE3 [7:0]
- SD_SAT_CR [7:0], SD Saturation Cr Channel, Address 0xE4 [7:0]
- SD_OFF_CB [7:0], SD Offset Cb Channel, Address 0xE1 [7:0]
- SD_OFF_CR [7:0], SD Offset Cr Channel, Address 0xE2 [7:0]
- BRI [7:0], Brightness Adjust, Address 0x0A [7:0]
- HUE [7:0], Hue Adjust, Address 0x0B [7:0]
- DEF_Y [5:0], Default Value Y, Address 0x0C [7:2]
- DEF_C [7:0], Default Value C, Address 0x0D [7:0]
- DEF_VAL_EN, Default Value Enable, Address 0x0C [0]
- DEF_VAL_AUTO_EN, Default Value Automatic Enable, Address 0x0C [1]
- CLAMP OPERATION
- LUMA FILTER
- CHROMA FILTER
- GAIN OPERATION
- Luma Gain
- Chroma Gain
- CAGC [1:0], Chroma Automatic Gain Control, Address 0x2C [1:0]
- CAGT [1:0], Chroma Automatic Gain Timing, Address 0x2D [7:6]
- CMG [11:0]/CG [11:0], Chroma Manual Gain/Chroma Gain, Address 0x2D [3:0], Address 0x2E [7:0]
- CKE, Color-Kill Enable, Address 0x2B [6]
- CKILLTHR [2:0], Color-Kill Threshold, Address 0x3D [6:4]
- CHROMA TRANSIENT IMPROVEMENT (CTI)
- DIGITAL NOISE REDUCTION (DNR) AND LUMA PEAKING FILTER
- COMB FILTERS
- NTSC Comb Filter Settings
- PAL Comb Filter Settings
- Vertical Blank Control
- NVBIOLCM [1:0], NTSC VBI Odd Field Luma Comb Mode, Address 0xEB [7:6]
- NVBIELCM [1:0], NTSC VBI Even Field Luma Comb Mode, Address 0xEB [5:4]
- PVBIOLCM [1:0], PAL VBI Odd Field Luma Comb Mode, Address 0xEB [3:2]
- PVBIELCM [1:0], PAL VBI Even Field Luma Comb Mode, Address 0xEB [1:0]
- NVBIOCCM [1:0], NTSC VBI Odd Field Chroma Comb Mode, Address 0xEC [7:6]
- NVBIECCM [1:0], NTSC VBI Even Field Chroma Comb Mode, Address 0xEC [5:4]
- PVBIOCCM [1:0], PAL VBI Odd Field Chroma Comb Mode, Address 0xEC [3:2]
- PVBIECCM [1:0], PAL VBI Even Field Chroma Comb Mode, Address 0xEC [1:0]
- AV CODE INSERTION AND CONTROLS
- BT656-4, ITU-R BT.656-4 Enable, Address 0x04 [7]
- SD_DUP_AV, Duplicate AV Codes, Address 0x03 [0]
- VBI_EN, Vertical Blanking Interval Data Enable, Address 0x03 [7]
- BL_C_VBI, Blank Chroma During VBI, Address 0x04 [2]
- RANGE, Range Selection, Address 0x04 [0]
- AUTO_PDC_EN, Automatic Programmed Delay Control, Address 0x27 [6]
- LTA [1:0], Luma Timing Adjust, Address 0x27 [1:0]
- CTA [2:0], Chroma Timing Adjust, Address 0x27 [5:3]
- SYNCHRONIZATION OUTPUT SIGNALS
- HS Configuration
- VS and FIELD Configuration
- NEWAVMODE, New AV Mode, Address 0x31 [4]
- HVSTIM, Horizontal VS Timing, Address 0x31 [3]
- VSBHO, VS Begin Horizontal Position Odd, Address 0x32 [7]
- VSBHE, VS Begin Horizontal Position Even, Address 0x32 [6]
- VSEHO VS, End Horizontal Position Odd, Address 0x33 [7]
- VSEHE, VS End Horizontal Position Even, Address 0x33 [6]
- PVS, Polarity VS, Address 0x37 [5]
- PF, Polarity FIELD, Address 0x37 [3]
- NVBEGDELO, NTSC Vsync Begin Delay on Odd Field, Address 0xE5 [7]
- NVBEGDELE, NTSC Vsync Begin Delay on Even Field, Address 0xE5 [6]
- NVBEGSIGN, NTSC Vsync Begin Sign, Address 0xE5 [5]
- NVBEG [4:0], NTSC Vsync Begin, Address 0xE5 [4:0]
- NVENDDELO, NTSC Vsync End Delay on Odd Field, Address 0xE6 [7]
- NVENDDELE, NTSC Vsync End Delay on Even Field, Address 0xE6 [6]
- NVENDSIGN, NTSC Vsync End Sign, Address 0xE6 [5]
- NVEND [4:0], NTSC Vsync End, Address 0xE6 [4:0]
- NFTOGDELO, NTSC Field Toggle Delay on Odd Field, Address 0xE7 [7]
- NFTOGDELE, NTSC Field Toggle Delay on Even Field, Address 0xE7 [6]
- NFTOGSIGN, NTSC Field Toggle Sign, Address 0xE7 [5]
- NFTOG [4:0], NTSC Field Toggle, Address 0xE7 [4:0]
- PVBEGDELO, PAL Vsync Begin Delay on Odd Field, Address 0xE8 [7]
- PVBEGDELE, PAL Vsync Begin Delay on Even Field, Address 0xE8 [6]
- PVBEGSIGN, PAL Vsync Begin Sign, Address 0xE8 [5]
- PVBEG [4:0], PAL Vsync Begin, Address 0xE8 [4:0]
- PVENDDELO, PAL Vsync End Delay on Odd Field, Address 0xE9 [7]
- PVENDDELE, PAL Vsync End Delay on Even Field, Address 0xE9 [6]
- PVENDSIGN, PAL Vsync End Sign, Address 0xE9 [5]
- PVEND [4:0], PAL Vsync End, Address 0xE9 [4:0]
- PFTOGDELO, PAL Field Toggle Delay on Odd Field, Address 0xEA [7]
- PFTOGDELE, PAL Field Toggle Delay on Even Field, Address 0xEA [6]
- PFTOGSIGN, PAL Field Toggle Sign, Address 0xEA [5]
- PFTOG, PAL Field Toggle, Address 0xEA [4:0]
- SYNC PROCESSING
- VBI DATA DECODE
- VDP Default Configuration
- VDP Manual Configuration
- MAN_LINE_PGM, Enable Manual Line Programming of VBI Standards, Address 0x64 [7], User Sub Map
- VBI_DATA_Px_Ny [3:0], VBI Standard to be Decoded on Line x for PAL, Line y for NTSC, Addresses 0x64 to 0x77, User Sub Map
- VDP_TTXT_TYPE_MAN_ENABLE, Enable Manual Selection of Teletext Type, Address 0x60 [2], User Sub Map
- VDP_TTXT_TYPE_MAN [1:0], Specify the Teletext Type, Address 0x60 [1:0], User Sub Map
- VDP Ancillary Data Output
- ADF_ENABLE, Enable Ancillary Data Output Through 656 Stream, Address 0x62 [7], User Sub Map
- ADF_DID [4:0], User-Specified Data ID Word in Ancillary Data, Address 0x62 [4:0], User Sub Map
- ADF_SDID [5:0], User-Specified Secondary Data ID Word in Ancillary Data, Address 0x63 [5:0], User Sub Map
- DUPLICATE_ADF, Enable Duplication/Spreading of Ancillary Data over Y and C Buses, Address 0x63 [7], User Sub Map
- ADF_MODE [1:0], Determine the Ancillary Data Output Mode, Address 0x62 [6:5], User Sub Map
- Structure of VBI Words in Ancillary Data Stream
- VDP Framing Code
- I2C INTERFACE
- STANDARD DETECTION AND IDENTIFICATION
- Notes
- STDI_DVALID, Standard Identification Data Valid Read Back, Address 0xB1 [7]
- STDI_LINE_COUNT_MODE, Address 0x86 [3]
- BL [13:0], Block Length Readback, Address 0xB1 [5:0], Address 0xB2 [7:0]
- LCVS [4:0], Line Count in Vsync Readback, Address 0xB3 [7:3]
- LCF [10:0], Line Count in Field Readback, Address 0xB3 [2:0], Address 0xB4 [7:0]
- FCL [12:0], 1/256th of Field Length in Number of Crystal Clocks Read back, Address 0xCA [4:0], Address 0xCB [7:0]
- STDI Readback Values for SD, PR, and HD
- I2C READBACK REGISTERS
- Teletext
- CGMS and WSS
- CC
- CC_CLEAR, Closed Captioning Clear, Address 0x78 [0], User Sub Map, Write Only, Self-Clearing
- CC_AVL, Closed Captioning Available, Address 0x78 [0], User Sub Map, Read Only
- CC_EVEN_FIELD, Address 0x78 [1], User Sub Map, Read Only
- VDP_CCAP_DATA_0, Address 0x79 [7:0], User Sub Map, Read Only
- VDP_CCAP_DATA_1, Address 0x7A [7:0], User Sub Map, Read Only
- VITC
- VPS/PDC/UTC/Gemstar
- I2C_GS_VPS_PDC_UTC (VDP) [1:0], Address 0x9C [6:5], User Sub Map
- GS_PDC_VPS_UTC_CLEAR, GS/PDC/VPS/UTC Clear, Address 0x78 [4], User Sub Map, Write Only, Self-Clearing
- GS_PDC_VPS_UTC_AVL, GS/PDC/VPS/UTC Available, Address 0x78 [4], User Sub Map, Read Only
- VDP_GS_VPS_PDC_UTC Readback Registers, Addresses 0x84 to 0x90, User Sub Map
- VPS
- Gemstar
- AUTO_DETECT_GS_TYPE, Address 0x61 [4], User Sub Map
- GS_DATA_TYPE, Address 0x78 [5], User Sub Map, Read Only
- PDC/UTC
- VBI System 2
- Gemstar Data Recovery
- GDE_SEL_OLD_ADF, Address 0x4C [3], User Map
- Gemstar Bit Names
- Gemstar 2× Format, Half-Byte Output Mode
- Gemstar 1× Format, Half-Byte Output Mode
- NTSC CC Data
- PAL CC Data
- GDECEL [15:0], Gemstar Decoding Even Lines, Address 0x48 [7:0], Address 0x49 [7:0]
- GDECOL [15:0], Gemstar Decoding Odd Lines, Address 0x4A [7:0], Address 0x4B [7:0]
- GDECAD, Gemstar Decode Ancillary Data Format, Address 0x4C [0]
- Letterbox Detection
- Detection at the Start of a Field
- Detection at the End of a Field
- Detection at the Midrange
- LB_LCT [7:0], Letterbox Line Count Top, Address 0x9B [7:0]; LB_LCM [7:0], Letterbox Line Count Mid, Address 0x9C [7:0]; LB_LCB [7:0], Letterbox Line Count Bottom, Address 0x9D [7:0]
- LB_TH [4:0], Letterbox Threshold Control, Address 0xDC [4:0]
- LB_SL [3:0], Letterbox Start Line, Address 0xDD [7:4]
- LB_EL [3:0], Letterbox End Line, Address 0xDD [3:0]
- IF Compensation Filter
- I2C Interrupt System
- Interrupt Request Output Operation
- INTRQ_DUR_SEL [1:0], Interrupt Duration Select, Address 0x40 [7:6], User Sub Map
- Interrupt Drive Level
- INTRQ_OP_SEL [1:0], Interrupt Duration Select, Address 0x40 [1:0], User Sub Map
- Multiple Interrupt Events
- Macrovision Interrupt Selection Bits
- MV_INTRQ_SEL [1:0], Macrovision Interrupt Selection Bits, Address 0x40 [5:4], User Sub Map
- PIXEL PORT CONFIGURATION
- MPU PORT DESCRIPTION
- I2C REGISTER MAPS
- PCB LAYOUT RECOMMENDATIONS
- TYPICAL CIRCUIT CONNECTION
- OUTLINE DIMENSIONS

ADV7188
Rev. A | Page 55 of 112
Table 67. VBI Data Standards for Manual Configuration
VBI_DATA_Px_Ny PAL—625/50 NTSC—525/60
0000 Disable VDP Disable VDP
0001 Teletext system identified by VDP_TTXT_TYPE Teletext system identified by VDP_TTXT_TYPE
0010 VPS—ETSI EN 300 231 V 1.3.1 Reserved
0011 VITC VITC
0100 WSS ITU-R BT.1119-1/ETSI.EN.300294 CGMS EIA-J CPR-1204/IEC 61880
0101 Reserved Gemstar 1×
0110 Reserved Gemstar 2×
0111 CC CC EIA-608
1000 to 1111 Reserved Reserved
Table 68. VBI Data Standards to be Decoded on Line Px (PAL) or Line Ny (NTSC)
Address
Signal Name Register Location Dec Hex
VBI_DATA_P6_N23 VDP_LINE_00F [7:4] 101 0x65
VBI_DATA_P7_N24 VDP_LINE_010 [7:4] 102
0x66
VBI_DATA_P8_N25 VDP_LINE_011 [7:4] 103
0x67
VBI_DATA_P9 VDP_LINE_012 [7:4] 104
0x68
VBI_DATA_P10 VDP_LINE_013 [7:4] 105
0x69
VBI_DATA_P11 VDP_LINE_014 [7:4] 106
0x6A
VBI_DATA_P12_N10 VDP_LINE_015 [7:4] 107
0x6B
VBI_DATA_P13_N11 VDP_LINE_016 [7:4] 108
0x6C
VBI_DATA_P14_N12 VDP_LINE_017 [7:4] 109
0x6D
VBI_DATA_P15_N13 VDP_LINE_018 [7:4] 110
0x6E
VBI_DATA_P16_N14 VDP_LINE_019 [7:4] 111
0x6F
VBI_DATA_P17_N15 VDP_LINE_01A [7:4] 112
0x70
VBI_DATA_P18_N16 VDP_LINE_01B [7:4] 113
0x71
VBI_DATA_P19_N17 VDP_LINE_01C [7:4] 114
0x72
VBI_DATA_P20_N18 VDP_LINE_01D [7:4] 115
0x73
VBI_DATA_P21_N19 VDP_LINE_01E [7:4] 116
0x74
VBI_DATA_P22_N20 VDP_LINE_01F [7:4] 117
0x75
VBI_DATA_P23_N21 VDP_LINE_020 [7:4] 118
0x76
VBI_DATA_P24_N22 VDP_LINE_021 [7:4] 119
0x77
VBI_DATA_P318 VDP_LINE_00E [3:0] 100
0x64
VBI_DATA_P319_N286 VDP_LINE_00F [3:0] 101
0x65
VBI_DATA_P320_N287 VDP_LINE_010 [3:0] 102
0x66
VBI_DATA_P321_N288 VDP_LINE_011 [3:0] 103
0x67
VBI_DATA_P322 VDP_LINE_012 [3:0] 104
0x68
VBI_DATA_P323 VDP_LINE_013 [3:0] 105
0x69
VBI_DATA_P324_N272 VDP_LINE_014 [3:0] 106
0x6A
VBI_DATA_P325_N273 VDP_LINE_015 [3:0] 107
0x6B
VBI_DATA_P326_N274 VDP_LINE_016 [3:0] 108
0x6C
VBI_DATA_P327_N275 VDP_LINE_017 [3:0] 109
0x6D
VBI_DATA_P328_N276 VDP_LINE_018 [3:0] 110
0x6E
VBI_DATA_P329_N277 VDP_LINE_019 [3:0] 111
0x6F
VBI_DATA_P330_N278 VDP_LINE_01A [3:0] 112
0x70
VBI_DATA_P331_N279 VDP_LINE_01B [3:0] 113
0x71
VBI_DATA_P332_N280 VDP_LINE_01C [3:0] 114
0x72
VBI_DATA_P333_N281 VDP_LINE_01D [3:0] 115
0x73
VBI_DATA_P334_N282 VDP_LINE_01E [3:0] 116
0x74
VBI_DATA_P335_N283 VDP_LINE_01F [3:0] 117
0x75
VBI_DATA_P336_N284 VDP_LINE_020 [3:0] 118
0x76
VBI_DATA_P337_N285 VDP_LINE_021 [3:0] 119
0x77