Datasheet

Table Of Contents
ADV7188
Rev. A | Page 52 of 112
05478-034
ADVANCE BEGIN OF
VSYNC BY PVBEG[4:0]
DELAY BEGIN OF
VSYNC BY PVBEG[4:0]
VSYNC BEGIN
PVBEGSIGN
ODD FIELD?
01
NOYES
PVBEGDELO
VSBHO
ADDITIONAL
DELAY BY
1 LINE
ADVANCE BY
0.5 LINE
1 0
1 0
PVBEGDELE
VSBHE
ADDITIONAL
DELAY BY
1 LINE
ADVANCE BY
0.5 LINE
10
10
NOT VALID FOR USER
PROGRAMMING
Figure 34. PAL Vsync Begin
PVENDDELO, PAL Vsync End Delay on Odd Field,
Address 0xE9 [7]
0 (default)—No delay.
1—Delays vsync going low on an odd field by a line relative
to PVEND.
PVENDDELE, PAL Vsync End Delay on Even Field,
Address 0xE9 [6]
0 (default)—No delay.
1—Delays vsync going low on an even field by a line relative
to PVEND.
PVENDSIGN, PAL Vsync End Sign, Address 0xE9 [5]
0 (default)—Delays the end of vsync. Set for user manual
programming.
1—Advances the end of vsync. Not recommended for user
programming.
05478-035
ADVANCE END OF
VSYNC BY PVEND[4:0]
DELAY END OF VSYNC
BY PVEND[4:0]
VSYNC END
PVENDSIGN
ODD FIELD?
01
NOYES
PVENDDELO
VSEHO
ADDITIONAL
DELAY BY
1 LINE
ADVANCE BY
0.5 LINE
1 0
1 0
PVENDDELE
VSEHE
ADDITIONAL
DELAY BY
1 LINE
ADVANCE BY
0.5 LINE
10
10
NOT VALID FOR USER
PROGRAMMING
Figure 35. PAL Vsync End
PVEND [4:0], PAL Vsync End, Address 0xE9 [4:0]
The default value of PVEND is 10100, indicating the PAL vsync
end position.
For all NTSC/PAL vsync timing controls, both the V bit in the
AV code and the vsync on the VS pin are modified.
PFTOGDELO, PAL Field Toggle Delay on Odd Field,
Address 0xEA [7]
0 (default)—No delay.
1—Delays the F toggle/transition on an odd field by a line
relative to PFTOG.
PFTOGDELE, PAL Field Toggle Delay on Even Field,
Address 0xEA [6]
0 (default)—No delay.
1 (default)—Delays the F toggle/transition on an even field by a
line relative to PFTOG.