Rev. B | Page 7 of 16
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 10.
Parameter Rating
Storage Temperature (T
ST
) −55°C to +150°C
Ambient Operating Temperature (T
A
) −40°C to +105°C
Supply Voltages (V
DDx
, V
ISO
)
1
−0.5 V to +7.0 V
Input Voltage (RC
SEL
, RC
IN
, V
SEL
)
1, 2
−0.5 V to V
DDI
+ 0.5 V
Output Voltage (RC
OUT
)
1, 2
−0.5 V to V
DDO
+ 0.5 V
Average Total Output Current
3
I
ISO
100 mA
Common-Mode Transients
4
−100 kV/µs to +100 kV/µs
1
Each voltage is relative to its respective ground.
2
V
DDI
and V
DDO
refer to the supply voltages on the input and output sides of a
given channel, respectively. See the PCB Layout section.
3
See Figure 2 for maximum rated current values for various temperatures.
4
Refers to common-mode transients across the isolation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause
latch-up or permanent damage.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 11. Maximum Continuous Working Voltage
1
Parameter Max Unit Reference Standard
AC Voltage
Bipolar Waveform
424
V peak
50-year minimum
lifetime
Unipolar Waveform
Basic Insulation 600 V peak
Maximum approved
working voltage per
IEC 60950-1
Reinforced Insulation 353 V peak Maximum approved
working voltage per
IEC 60950-1
DC Voltage
Basic Insulation 600 V peak
Maximum approved
working voltage per
IEC 60950-1
Reinforced Insulation 353 V peak Maximum approved
working voltage per
IEC 60950-1
1
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.