Datasheet
Table Of Contents
ADuM4160 Data Sheet
Rev. D | Page 6 of 16
RECOMMENDED OPERATING CONDITIONS
Table 6.
Parameter Symbol Min Max Unit
Operating Temperature T
A
−40 +105 °C
Supply Voltages
1
V
BUS1
, V
BUS2
3.1 5.5 V
Input Signal Rise and Fall Times 1.0 ms
1
All voltages are relative to their respective ground. See the section for information on immunity to external magnetic
fields.
DC Correctness and Magnetic Field Immunity