Datasheet
ADuM1400/ADuM1401/ADuM1402 Data Sheet
Rev. L | Page 20 of 31
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.
Table 11.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input to Output Test Voltage, Method B1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V peak
Input to Output Test Voltage, Method A V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1 896 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 672 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
4000 V peak
Safety Limiting Values Maximum value allowed in the event of a failure
(see Figure 4)
Case Temperature T
S
150 °C
Side 1 Current I
S1
265 mA
Side 2 Current I
S2
335 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
350
300
250
200
150
100
50
50 100 150 200
SIDE #1
SIDE #2
03786-004
Figure 4. Thermal Derating Curve, Dependence of Safety Limiting Values
with Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 12.
Parameter Rating
Operating Temperature (T
A
)
1
−40°C to +105°C
Operating Temperature (T
A
)
2
−40°C to +125°C
Supply Voltages (V
DD1
, V
DD2
)
1, 3
2.7 V to 5.5 V
Supply Voltages (V
DD1
, V
DD2
)
2, 3
3.0 V to 5.5 V
Input Signal Rise and Fall Times 1.0 ms
1
Does not apply to ADuM1400W, ADuM1401W, and ADuM1402W automotive
grade versions.
2
Applies to ADuM1400W, ADuM1401W, and ADuM1402W automotive grade
versions.
3
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to
external magnetic fields.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.