Datasheet
Table Of Contents
- Features
- Applications
- General Description
- Functional Block Diagrams
- Table of Contents
- Specifications
- Electrical Characteristics—5 V, 105°C Operation
- Electrical Characteristics—3 V, 105°C Operation
- Electrical Characteristics—Mixed 5 V/3 V or 3 V/5 V, 105°C OPERATION
- Electrical Characteristics—5 V, 125°C Operation
- Electrical Characteristics—3 V, 125°C Operation
- Electrical Characteristics—Mixed 5 V/3 V, 125°C Operation
- Electrical Characteristics—Mixed 3 V/5 V, 125°C Operation
- Package Characteristics
- Regulatory Information
- Insulation and Safety-Related Specifications
- DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics
- Recommended Operation Conditions
- Absolute Maximum Ratings
- Pin Configurations and Function Descriptions
- Typical Performance Characteristics
- Applications Information
- Outline Dimensions
ADuM1400/ADuM1401/ADuM1402 Data Sheet
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.
Table 11.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification
40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input-to-Output Test Voltage, Method B1
V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V peak
Input-to-Output Test Voltage, Method A V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1
896
V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 672 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
4000 V peak
Safety-Limiting Values
Maximum value allowed in the event of a failure
(see Figure 4)
Case Temperature T
S
150 °C
Side 1 Current I
S1
265 mA
Side 2 Current I
S2
335 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values
with Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 12.
Parameter Rating
Operating Temperature (T
A
)
1
−40°C to +105°C
Operating Temperature (T
A
)
2
−40°C to +125°C
Supply Voltages (V
DD1
, V
DD2
)
1,
3
2.7 V to 5.5 V
Supply Voltages (V
DD1
, V
DD2
)
2, 3
3.0 V to 5.5 V
Input Signal Rise and Fall Times 1.0 ms
1
Does not apply to ADuM1400W, ADuM1401W, and ADuM1402W automotive
grade versions.
2
Applies to ADuM1400W, ADuM1401W, and ADuM1402W automotive grade
versions.
3
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to
external magnetic fields.
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
350
300
250
200
150
100
50
50 100 150 200
SIDE #1
SIDE #2
03786-004
Rev. I | Page 20 of 32