PACKAGE CHARACTERISTICS
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions
Resistance (Input-to-Output)
1
R
I-O
10
12
Capacitance (Input-to-Output)
1
C
I-O
1.0 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
46 °C/W Thermocouple located at
center of package underside
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
41 °C/W
Package Power Dissipation P
PD
240 mW
1
The device is considered a 2-terminal device; Pin 1, Pin 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
2
Input capacitance is measured at Pin 2 (V
I
).
REGULATORY INFORMATION
The ADuM1100 is approved by the following organizations.
Table 5.
UL CSA CQC VDE
Recognized Under
1577 Component
Recognition
Program
1
Approved under CSA
Component Acceptance
Notice 5A
Approved under
CQC11-471543-2012
Certified according to
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12
2
Single/Basic Insulation,
2500 V rms Isolation
Voltage
Basic insulation per
CSA 60950-1-03 and IEC
60950-1, 400 V rms
(565 V peak) maximum
working voltage
Basic insulation per GB4943.1-
2011 400 V rms (588 V peak)
maximum working voltage,
tropical climate, altitude
5000 meters
Reinforced insulation, 560 V peak
File E214100 File 205078 File CQC14001117247 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM1100 is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 µA).
2
In accordance with DIN V VDE V 0884-10, each ADuM1100 is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Conditions
Minimum External Air Gap (Clearance) L(I01) 4.90 min mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 4.01 min mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.016 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table I)
Maximum Working Voltage Compatible with
50 Years Service Life
V
IORM