Table 34. Commonly Used Baud Rates Using Timer 3 with the 16.777216 MHz PLL Clock
Ideal Baud CD DIV T3CON T3FD % Error
230400 0 2 82H 09H 0.25
115200 0 3 83H 09H 0.25
115200 1 2 82H 09H 0.25
115200 2 1 81H 09H 0.25
57600 0 4 84H 09H 0.25
57600 1 3 83H 09H 0.25
57600 2 2 82H 09H 0.25
57600 3 1 81H 09H 0.25
38400 0 4 84H 2DH 0.2
38400 1 3 83H 2DH 0.2
38400 2 2 82H 2DH 0.2
38400 3 1 81H 2DH 0.2
19200 0 5 85H 2DH 0.2
19200 1 4 84H 2DH 0.2
19200 2 3 83H 2DH 0.2
19200 3 2 82H 2DH 0.2
19200 4 1 81H 2DH 0.2
9600 0 6 86H 2DH 0.2
9600 1 5 85H 2DH 0.2
9600 2 4 84H 2DH 0.2
9600 3 3 83H 2DH 0.2
9600 4 2 82H 2DH 0.2
9600 5 1 81H 2DH 0.2