Datasheet
REV. 0
ADuC831
–7–
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
ADuC831 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
ORDERING GUIDE
Temperature Package Package
Model Range Description Option
ADuC831BS –40°C to +125°C 52-Lead Plastic Quad Flatpack S-52
ADuC831BCP –40°C to +85°C 56-Lead Chip Scale Package CP-56
EVAL-ADuC831QS QuickStart Development System
EVAL-ADuC831QSP
QuickStart Plus Development System
ABSOLUTE MAXIMUM RATINGS*
(T
A
= 25°C unless otherwise noted.)
AV
DD
to DV
DD
. . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +0.3 V
AGND to DGND . . . . . . . . . . . . . . . . . . . . –0.3 V to +0.3 V
DV
DD
to DGND, AV
DD
to AGND . . . . . . . . . –0.3 V to +7 V
Digital Input Voltage to DGND . . . . –0.3 V to DV
DD
+ 0.3 V
Digital Output Voltage to DGND . . . –0.3 V to DV
DD
+ 0.3 V
V
REF
to AGND . . . . . . . . . . . . . . . . . –0.3 V to AV
DD
+ 0.3 V
Analog Inputs to AGND . . . . . . . . . . –0.3 V to AV
DD
+ 0.3 V
Operating Temperature Range Industrial
ADuC831BS . . . . . . . . . . . . . . . . . . . . . . –40°C to +125°C
Operating Temperature Range Industrial
ADuC831BCP . . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
θ
JA
Thermal Impedance (ADuC831BS) . . . . . . . . . . 90°C/W
θ
JA
Thermal Impedance (ADuC831BCP) . . . . . . . . . 52°C/W
Lead Temperature, Soldering
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . 215°C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . 220°C
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.