Datasheet

ADT75 Data Sheet
Rev. B | Page 14 of 24
Temperature Value Register
This 16-bit read only register stores the temperature measured
by the internal temperature sensor. The temperature is stored in
twos complement format with the MSB being the temperature
sign bit. When reading from this register, the eight MSBs (Bit
D15 to Bit D8) are read first and then the eight LSBs (Bit D7 to
Bit D0) are read. The control register settings are the default
settings on power up.
Configuration Register
This 8-bit read/write register stores various configuration modes
for the ADT75. These modes are shutdown, overtemperature
interrupt, one-shot, SMBus alert function enable, OS/ALERT
pin polarity, and overtemperature fault queues. See Table 10.
MSB
LSB
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0 0 0 0 0 0 0 0 0 0 0 0 N/A
1
N/A
1
N/A
1
N/A
1
1
N/A = not applicable.
Table 10.
Bit Configuration Mode Default Setting at Power-Up
D7 OS/SMBus alert 0
D6 Reserved 0
D5 One-shot 0
D4 Fault queue 0
D3 Fault queue 0
D2 OS/ALERT pin polarity 0
D1
Cmp/Int
0
D0 Shutdown 0