Datasheet
Rev. B | Page 40 of 44 | July 2013
ADSP-BF592
ENVIRONMENTAL CONDITIONS
To determine the junction temperature on the application
printed circuit board use:
where:
T
J
= junction temperature (°C)
T
CASE
= case temperature (°C) measured by customer at top cen-
ter of package.
JT
= from Table 32
P
D
= power dissipation (see Total Power Dissipation on Page 19
for the method to calculate P
D
)
Values of
JA
are provided for package comparison and printed
circuit board design considerations.
JA
can be used for a first
order approximation of T
J
by the equation:
where:
T
A
= ambient temperature (°C)
Values of
JC
are provided for package comparison and printed
circuit board design considerations when an external heat sink
is required.
Values of
JB
are provided for package comparison and printed
circuit board design considerations.
In Table 32, airflow measurements comply with JEDEC stan-
dards JESD51-2 and JESD51-6, and the junction-to-board
measurement complies with JESD51-8. The junction-to-case
measurement complies with MIL-STD-883 (Method 1012.1).
All measurements use a 2S2P JEDEC test board.
Table 32. Thermal Characteristics
Parameter Condition Typical Unit
θ
JA
0 linear m/s air flow 23.5 °C/W
θ
JMA
1 linear m/s air flow 20.9 °C/W
θ
JMA
2 linear m/s air flow 20.2 °C/W
θ
JB
11.2 °C/W
θ
JC
9.5 °C/W
Ψ
JT
0 linear m/s air flow 0.21 °C/W
Ψ
JT
1 linear m/s air flow 0.36 °C/W
Ψ
JT
2 linear m/s air flow 0.43 °C/W
T
J
T
CASE
JT
P
D
+=
T
J
T
A
JA
P
D
+=