Datasheet
Rev. D | Page 79 of 88 | July 2013
ADSP-BF522/ADSP-BF523/ADSP-BF524/ADSP-BF525/ADSP-BF526/ADSP-BF527
ENVIRONMENTAL CONDITIONS
To determine the junction temperature on the application
printed circuit board use:
where:
T
J
= Junction temperature (°C)
T
CASE
= Case temperature (°C) measured by customer at top
center of package.
JT
= From Table 66
P
D
= Power dissipation — For a description, see Total Power
Dissipation on Page 35.
Values of
JA
are provided for package comparison and printed
circuit board design considerations.
JA
can be used for a first
order approximation of T
J
by the equation:
where:
T
A
= Ambient temperature (°C)
Values of
JC
are provided for package comparison and printed
circuit board design considerations when an external heat sink
is required.
Values of
JB
are provided for package comparison and printed
circuit board design considerations.
In Table 66, airflow measurements comply with JEDEC stan-
dards JESD51-2 and JESD51-6, and the junction-to-board
measurement complies with JESD51-8. The junction-to-case
measurement complies with MIL-STD-883 (Method 1012.1).
All measurements use a 2S2P JEDEC test board.
Figure 74. Driver Type G Typical Rise and Fall Times (10%–90%) vs.
Load Capacitance (2.5V V
DDEXT
/V
DDMEM
)
Figure 75. Driver Type G Typical Rise and Fall Times (10%–90%) vs.
Load Capacitance (3.3V V
DDEXT
/V
DDMEM
)
4
RISE AND FALL TIME (10% TO 90%)
LOAD CAPACITANCE (pF)
0 50 100 150
6
0
1
2
5
200
t
RISE
t
FALL
3
7
t
RISE
= 2.5V @ 25
°
C
t
FALL
= 2.5V @ 25
°
C
8
9
3
RISE AND FALL TIME (10% TO 90%)
LOAD CAPACITANCE (pF)
0 50 100 150
9
5
0
1
2
4
200
t
RISE
t
FALL
t
RISE
= 3.3V @ 25
°
C
t
FALL
= 3.3V @ 25
°
C
6
8
7
T
J
T
CASE
JT
P
D
+=
Table 65. Thermal Characteristics for BC-208-1 Package
Parameter Condition Typical Unit
JA
0 linear m/s air flow 23.20 °C/W
JMA
1 linear m/s air flow 20.20 °C/W
JMA
2 linear m/s air flow 19.20 °C/W
JB
13.05 °C/W
JC
6.92 °C/W
JT
0 linear m/s air flow 0.18 °C/W
JT
1 linear m/s air flow 0.27 °C/W
JT
2 linear m/s air flow 0.32 °C/W
Table 66. Thermal Characteristics for BC-289-2 Package
Parameter Condition Typical Unit
JA
0 linear m/s air flow 34.5 °C/W
JMA
1 linear m/s air flow 31.1 °C/W
JMA
2 linear m/s air flow 29.8 °C/W
JB
20.3 °C/W
JC
8.8 °C/W
JT
0 linear m/s air flow 0.24 °C/W
JT
1 linear m/s air flow 0.44 °C/W
JT
2 linear m/s air flow 0.53 °C/W
T
J
T
A
JA
P
D
+=