Datasheet
ADSP-2181
–27–
REV. D
ENVIRONMENTAL CONDITIONS
Ambient Temperature Rating:
T
AMB
=T
CASE
– (PD × θ
CA
)
T
CASE
= Case Temperature in °C
PD = Power Dissipation in W
θ
CA
= Thermal Resistance (Case-to-Ambient)
θ
JA
= Thermal Resistance (Junction-to-Ambient)
θ
JC
= Thermal Resistance (Junction-to-Case)
Package θ
JA
θ
JC
θ
CA
TQFP 50°C/W 2°C/W 48°C/W
PQFP 41°C/W 10°C/W 31°C/W