PRECISE NEGATIVE VOLTAGE REFERENCE
The ADR512 is suitable for use in applications where a precise
negative voltage reference is desired, including the application
detailed in Figure 13.
Figure 14 shows the ADR512 configured to provide a 1.2 V
output.
ADR512
–1.2V
–V
DD
R2
+
03700-014
Figure 14. Precise 1.2 V Reference Configuration
Since the ADR512 characteristics resemble those of a Zener
diode, the cathode shown in Figure 14 will be 1.2 V higher with
respect to the anode (V+ with respect to Von the ADR512
package). Since the cathode of the ADR512 is tied to ground,
the anode must be 1.2 V.
R1 in Figure 14 should be chosen so that 100 μA to 10 mA is
provided to properly bias the ADR512.
I
V
R
DD
=1
(5)
The resistor R1 should be chosen so that power dissipation is at
a minimum. An ideal resistor value can be determined through
manipulation of Equation 5.