Datasheet

Data Sheet ADR5040/ADR5041/ADR5043/ADR5044/ADR5045
Rev. B | Page 5 of 16
Parameter Symbol Conditions Min Typ Max Unit
TEMPERATURE COEFFICIENT
1
TCV
OUT
40°C < T
A
< +125°C
Grade A 10 100 ppm/°C
Grade B 10 75 ppm/°C
OUTPUT VOLTAGE CHANGE vs. I
IN
∆V
R
I
IN
= 50 µA to 1 mA
40°C < T
A
< +125°C 0.7 3 mV
I
IN
= 1 mA to 15 mA
40°C < T
A
< +125°C 4 8 mV
DYNAMIC OUTPUT IMPEDANCE (∆V
R
/∆I
R
) I
IN
= 50 µA to 15 mA 0.2
MINIMUM OPERATING CURRENT I
IN
T
A
= 25°C 50 µA
40°C < T
A
< +125°C 60 µA
VOLTAGE NOISE
e
N
I
IN
= 100 µA; 0.1 Hz to 10 Hz
5.4
µV rms
I
IN
= 100 µA; 10 Hz to 10 kHz 240 µV rms
TURN-ON SETTLING TIME t
R
C
LOAD
= 0 µF 56 µs
OUTPUT VOLTAGE HYSTERESIS ∆V
OUT_HYS
I
IN
= 1 mA 40 ppm
1
Guaranteed by design.
ADR5045 ELECTRICAL CHARACTERISTICS
I
IN
= 50 µA to 15 mA, T
A
= 25°C, unless otherwise noted.
Table 6.
Parameter Symbol Conditions Min Typ Max Unit
OUTPUT VOLTAGE V
OUT
I
IN
= 100 µA
Grade A 4.990 5.000 5.010 V
Grade B 4.995 5.000 5.005 V
INITIAL ACCURACY V
OERR
I
IN
= 100 µA
Grade A –10 +10 mV
±0.2 %
Grade B –5 +5 mV
±0.1 %
TEMPERATURE COEFFICIENT
1
TCV
OUT
40°C < T
A
< +125°C
Grade A 10 100 ppm/°C
Grade B 10 75 ppm/°C
OUTPUT VOLTAGE CHANGE vs. I
IN
∆V
R
I
IN
= 50 µA to 1 mA
40°C < T
A
< +125°C 0.8 4 mV
I
IN
= 1 mA to 15 mA
40°C < T
A
< +125°C 4 8 mV
DYNAMIC OUTPUT IMPEDANCE (∆V
R
/∆I
R
) I
IN
= 50 µA to 15 mA 0.2
MINIMUM OPERATING CURRENT I
IN
T
A
= 25°C 50 µA
40°C < T
A
< +125°C 60 µA
VOLTAGE NOISE e
N
I
IN
= 100 µA; 0.1 Hz to 10 Hz 6.6 µV rms
I
IN
= 100 µA; 10 Hz to 10 kHz 280 µV rms
TURN-ON SETTLING TIME t
R
C
LOAD
= 0 µF 70 µs
OUTPUT VOLTAGE HYSTERESIS ∆V
OUT_HYS
I
IN
= 1 mA 40 ppm
1
Guaranteed by design.