Datasheet
ADR293
Rev. D | Page 3 of 12
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
V
S
= 6.0 V, T
A
= 25°C, unless otherwise noted.
Table 2.
Parameter Symbol Conditions Min Typ Max Unit
OUTPUT VOLTAGE V
OUT
I
OUT
= 0 mA
E Grade 4.997 5.000 5.003 V
F Grade 4.994 5.000 5.006 V
G Grade 4.990 5.000 5.010 V
INITIAL ACCURACY I
OUT
= 0 mA
E Grade –3 +3 mV
0.06 %
F Grade –6 +6 mV
0.12 %
G Grade –10 +10 mV
0.20 %
LINE REGULATION ΔV
OUT
/ΔV
IN
6.0 V to 15 V, I
OUT
= 0 mA
E, F Grades 30 100 ppm/V
G Grade 40 150 ppm/V
LOAD REGULATION ΔV
OUT
/ΔI
LOAD
V
S
= 6.0 V, I
OUT
= 0 mA to 5 mA
E, F Grades 30 100 ppm/mA
G Grade 40 150 ppm/mA
LONG-TERM STABILITY ΔV
OUT
After 1000 hours of operation @ 125°C 50 ppm
VOLTAGE NOISE e
N
p-p
f = 0.1 Hz to 10 Hz 15 μV p-p
VOLTAGE NOISE DENSITY e
N
f = 1 kHz 640 nV/√Hz
V
S
= 6.0 V, T
A
= −25°C to +85°C, unless otherwise noted.
Table 3.
Parameter Symbol Conditions Min Typ Max Unit
TEMPERATURE COEFFICIENT TCV
OUT
I
OUT
= 0 mA
E Grade 3 8 ppm/°C
F Grade 5 15 ppm/°C
G Grade 10 25 ppm/°C
LINE REGULATION ΔV
OUT
/ΔV
IN
6.0 V to 15 V, I
OUT
= 0 mA
E, F Grades 35 150 ppm/V
G Grade 50 200 ppm/V
LOAD REGULATION ΔV
OUT
/ΔI
LOAD
V
S
= 6.0 V, I
OUT
= 0 mA to 5 mA
E, F Grades 20 150 ppm/mA
G Grade 30 200 ppm/mA