Datasheet
ADR1581
Rev. 0 | Page 3 of 12
SPECIFICATIONS
T
A
= 25°C, I
IN
= 100 µA, unless otherwise noted.
Table 1.
ADR1581A ADR1581B
Parameter Min Typ Max Min Typ Max Unit
REVERSE VOLTAGE OUTPUT (SOT-23) 1.240 1.250 1.260 1.2485 1.250 1.2515 V
REVERSE VOLTAGE TEMPERATURE DRIFT
−40°C to +85°C 100 50 ppm/°C
MINIMUM OPERATING CURRENT, T
MIN
to T
MAX
60 60 A
REVERSE VOLTAGE CHANGE WITH REVERSE CURRENT
60 A < I
IN
< 10 mA, T
MIN
to T
MAX
2.5 6 2.5 6 mV
60 A < I
IN
< 1 mA, T
MIN
to T
MAX
0.8 0.8 mV
DYNAMIC OUTPUT IMPEDANCE (V
R
/∆I
R
)
I
IN
= 1 mA ± 100 A (f = 120 Hz) 0.4 1 0.4 0.5 Ω
OUTPUT NOISE
RMS Noise Voltage: 10 Hz to 10 kHz 20 20 V rms
Low Frequency Noise Voltage: 0.1 Hz to 10 Hz 4.5 4.5 V p-p
TURN-ON SETTLING TIME TO 0.1%
1
5 5 µs
OUTPUT VOLTAGE HYSTERESIS
2
80 80 µV
TEMPERATURE RANGE
Specified Performance, T
MIN
to T
MAX
−40 +85 −40 +85 °C
Operating Range
3
−55 +125 −55 +125 °C
1
Measured with a no load capacitor.
2
Output hysteresis is defined as the change in the +25°C output voltage after a temperature excursion to −40°C, then to +85°C, and back to +25°C.
3
The operating temperature range is defined as the temperature extremes at which the device continues to function. Parts may deviate from their specified
performance.