Datasheet
Data Sheet ADP8866
Rev. A | Page 25 of 52
Bit Name Bit No. Description
OVP_IEN 2 Overvoltage interrupt enabled. When the OVP_INT status bit is set after an error condition, an interrupt is raised to
the host if the OVP_IEN flag is enabled.
1 = the overvoltage interrupt is enabled.
0 = the overvoltage interrupt is disabled (OVP_INT flag is still asserted).
N/A [1:0] Reserved.
Independent Sink Interrupt Selection 1 (ISCOFF_SEL1)—Register 0x04
Table 16. ISCOFF_SEL1 Bit Map
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved D9OFFINT
Table 17.
Bit Name Bit No. Description
N/A [7:1] Reserved.
D9OFFINT
0
Include Diode 9 in the ISCOFF_INT flag.
1 = Diode 9 is in the group which triggers an ISCOFF_INT. When Diode 9 and all other LEDs with
DxOFFINT are set high and go from on to off, ISCOFF_INT is set.
0 = Diode 9 is not in the group which triggers an ISCOFF_INT when all diodes in that group are off.
Independent Sink Interrupt Selection 2 (ISCOFF_SEL2)—Register 0x05
Table 18. ISCOFF_SEL2 Bit Map
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
D8OFFINT D7OFFINT D6OFFINT D5OFFINT D4OFFINT D3OFFINT D2OFFINT D1OFFINT
Table 19.
Bit Name Bit No. Description
D8OFFINT 7 Include Diode 8 in the ISCOFF_INT flag.
1 = Diode 8 is in the group that triggers an ISCOFF_INT. When Diode 8 and all other LEDs with
DxOFFINT are set high and goes from on to off, ISCOFF_INT is set.
0 = Diode 8 is not in the group that triggers an ISCOFF_INT when all diodes in that group are off.
D7OFFINT 6 Include Diode 7 in the ISCOFF_INT flag.
1 = Diode 7 is in the group that triggers an ISCOFF_INT. When Diode 7 and all other LEDs with
DxOFFINT are set high and goes from on to off, ISCOFF_INT is set.
0 = Diode 7 is not in the group that triggers an ISCOFF_INT when all diodes in that group are off.
D6OFFINT 5 Include Diode 6 in the ISCOFF_INT flag.
1 = Diode 6 is in the group that triggers an ISCOFF_INT. When Diode 6 and all other LEDs with
DxOFFINT are set high and goes from on to off, ISCOFF_INT is set.
0 = Diode 6 is not in the group that triggers an ISCOFF_INT when all diodes in that group are off.
D5OFFINT 4 Include Diode 5 in the ISCOFF_INT flag.
1 = Diode 5 is in the group that triggers an ISCOFF_INT. When Diode 5 and all other LEDs with
DxOFFINT are set high and goes from on to off, ISCOFF_INT is set.
0 = Diode 5 is not in the group that triggers an ISCOFF_INT when all diodes in that group are off.
D4OFFINT 3 Include Diode 4 in the ISCOFF_INT flag.
1 = Diode 4 is in the group that triggers an ISCOFF_INT. When Diode 4 and all other LEDs with
DxOFFINT are set high and goes from on to off, ISCOFF_INT is set.
0 = Diode 4 is not in the group that triggers an ISCOFF_INT when all diodes in that group are off.
D3OFFINT 2 Include Diode 3 in the ISCOFF_INT flag.
1 = Diode 3 is in the group that triggers an ISCOFF_INT. When Diode 3 and all other LEDs with
DxOFFINT are set high and goes from on to off, ISCOFF_INT is set.
0 = Diode 3 is not in the group that triggers an ISCOFF_INT when all diodes in that group are off.