Bit No. Bit Name Access Default Description
2 EN_EOC R/W 1 0 = end of charge not allowed.
1 = end of charge allowed.
1 Not used
0 EN_CHG R/W 0 0 = battery charging is disabled.
1 = battery charging is enabled.
Table 26. Functional Settings 2, Register Address 0x08
Bit No. Bit Name Access Default Description
7 EN_JEITA R/W 0 = JEITA disabled 0 = JEITA compliance of the Li-Ion temperature battery charging
specifications is disabled.
1 = JEITA compliance enabled.
6 JEITA_SELECT R/W 0 = JEITA1 0 = JEITA1 is selected.
1 = JEITA2 is selected.
5
EN_CHG_VLIM
R/W
0
0 = charging voltage limit disabled.
1 = voltage limit activated. The charger prevents charging until the
battery voltage drops below the V
CHG_VLIM
threshold.
[4:3] IDEAL_DIODE[1:0] R/W 00 00 = ideal diode operates constantly when V
ISO_Sx
< V
ISO_Bx
.
01 = ideal diode operates when V
ISO_Sx
< V
ISO_Bx
and V
BAT _SNS
> V
WEAK
.
10 = ideal diode is disabled.
11 = ideal diode is disabled.
[2:0] VSYSTEM[2:0] R/W See Table 41 for
model specific
default value.
System
voltage programming bus. The values of the system voltage
can be programmed to the following values:
000 = 4.3 V.
001 = 4.4 V.
010 = 4.5 V.
011 = 4.6 V.
100 = 4.7 V.
101 = 4.8 V.
110 = 4.9 V.
111 = 5.0 V.
Table 27. Interrupt Enable, Register Address 0x09
Bit No. Bit Name Access Default Description
7
Not used
6 EN_THERM_LIM_INT R/W 0 0 = isothermal charging interrupt is disabled.
1 = isothermal charging interrupt is enabled.
5 EN_WD_INT R/W 0 0 = watchdog alarm interrupt is disabled.
1 = watchdog alarm interrupt is enabled.
4 EN_TSD_INT R/W 0 0 = overtemperature interrupt is disabled.
1 = overtemperature interrupt is enabled.
3 EN_THR_INT R/W 0 0 = THR temperature thresholds interrupt is disabled.
1 = THR temperature thresholds interrupt is enabled.
2 EN_BAT_INT R/W 0 0 = battery voltage thresholds interrupt is disabled.
1 = battery voltage thresholds interrupt is enabled.
1 EN_CHG_INT R/W 0 0 = charger mode change interrupt is disabled.
1 = charger mode change interrupt is enabled.
0
EN_VIN_INT
R/W
0
0 = VINx pin voltage thresholds interrupt is disabled.
1 = VINx pin voltage thresholds interrupt is enabled.