Bit No. Bit Name Access Default Description
[4:3] VTRK_DEAD[1:0] R/W 01 = 2.5 V Trickle to fast charge dead battery voltage programming bus. The
values of the trickle to fast charge threshold can be programmed to
the following values:
00 = 2.0 V.
01 = 2.5 V.
10 = 2.6 V.
11 = 2.9 V.
[2:0] VWEAK[2:0] R/W 011 = 3.0 V Weak battery voltage rising threshold.
000 = 2.7 V.
001 = 2.8 V.
010 = 2.9 V.
011 = 3.0 V.
100 = 3.1 V.
101 = 3.2 V.
110 = 3.3 V.
111 = 3.4 V.
Table 24. Timer Settings, Register Address 0x06
Bit No. Bit Name Access Default Description
[7:6] Not used
5 EN_TEND R/W 1 0 = charge complete timer, t
END
, disabled. A 31 ms deglitch timer
remains on.
1 = charge complete timer enabled.
4 EN_CHG_TIMER R/W 1 0 = trickle/fast charge timer disabled.
1 = trickle/fast charge timer enabled.
3 CHG_TMR_PERIOD R/W 1 Trickle and fast charge timer period.
0 = 30 sec trickle charge timer and 300 minute fast charge timer.
1 = 60 sec trickle charge timer and 600 minute fast charge timer.
2 EN_WD R/W 0 0 = watchdog timer is disabled even when BAT_SNS exceeds V
WEAK
.
1 = watchdog timer safety timer is enabled.
1
WD_PERIOD
R/W
0
Watchdog safety timer period.
0 = 32 sec watchdog timer and 40 minute safety timer.
1 = 64 sec watchdog timer and 40 minute safety timer.
0 RESET_WD W 0 When RESET_WD is set to logic high by I
2
C, the watchdog safety
timer is reset.
Table 25. Functional Settings 1, Register Address 0x07
Bit No. Bit Name Access Default Description
7 Not used
6 DIS_IC1 R/W 0 0 = normal operation.
1 = the ADP5062 is disabled; V
VINx
must be V
ISO_Bx
< V
VINx
< 5.5 V.
5 EN_BMON R/W 0 0 = when V
VINx
< V
VIN_OK_RISE
or V
VIN_OK_FALL
, the battery monitor is
disabled. When V
VINx
= 4.0 V to 6.7 V, the battery monitor is enabled
regardless of the EN_BMON state.
1 = the battery monitor is enabled even when the voltage at the
VINx pins is below V
VIN_OK
.
4 EN_THR R/W 0 0 = when V
VINx
< V
VIN_OK_RISE
or V
VIN_OK_FALL
, the THR current source is
disabled. When V
VINx
= 4.0 V to 6.7 V, the THR current source is
enabled regardless of the EN_THR state.
1 = THR current source is enabled even when the voltage at the
VINx pins is below V
VIN_OK_RISE
or V
VIN_OK_FALL
.
3 DIS_LDO R/W 0 0 = LDO is enabled.
1 = LDO is off. In addition, if EN_CHG = low, the battery isolation
FET is on. If EN_CHG = high, the battery isolation FET is off.