Datasheet

ADP5062 Data Sheet
Rev. B | Page 28 of 44
REGISTER BIT DESCRIPTIONS
In Table 18 through Table 33, the following abbreviations are used: R is read only, W is write only, R/W is read/write, and N/A means not
applicable.
Table 18. Manufacturer and Model ID, Register Address 0x00
Bit No. Bit Name Access Default Description
[7:4] MANUF[3:0] R 0001 The 4-bit manufacturer identification bus
[3:0] MODEL[3:0] R 1001 The 4-bit model identification bus
Table 19. Silicon Revision, Register Address 0x01
Bit No. Bit Name Access Default Description
[7:4] Not used R
[3:0] REV[3:0] R 0100/ADP5062ACPZ-1-R7
0111/ADP5062ACPZ-2-R7
The 4-bit silicon revision identification bus
Table 20. VINx Pin Settings, Register Address 0x02
Bit No. Bit Name Access Default Description
[7:5] Not used R
4
RFU
R/W
0
Reserved for future use.
[3:0] ILIM[3:0] R/W 0000 = 100 mA VINx input current-limit programming bus. The current into VINx can
be limited to the following programmed values:
0000 = 100 mA.
0001 = 150 mA.
0010 = 200 mA.
0011 = 250 mA.
0100 = 300 mA.
0101 = 400 mA.
0110 = 500 mA.
0111 = 600 mA.
1000 = 700 mA.
1001 = 800 mA.
1010 = 900 mA.
1011 = 1000 mA.
1100 = 1200 mA.
1101 = 1500 mA.
1110 = 1800 mA.
1111 = 2100 mA.