Datasheet
Data Sheet ADP5061
Rev. C | Page 41 of 44
DIG_IO1, DIG_IO2, and DIG_IO3 Options
Table 49. DIG_IO1 Polarity
Table 50.
DIG_IOx Options
Option Selection
0 = DIG_IO1 polarity, high active operation 0 = high active
1 = DIG_IO1 polarity, low active operation
Option DIG_IO1 Function DIG_IO2 Function DIG_IO3 Function Selection / Model
0000 I
VINx
limit Disable IC1 Charging disable/enable 0000
Low = 100 mA Low = not activated Low = charging disable ADP5061ACBZ-2-R7
High = 500 mA High = activated High = charging enabled ADP5061ACBZ-4-R7
0010 I
VINx
limit I
VINx
limit Disable IC1
Low = 100 mA Not applicable Low = not activated
High= 500 mA High = I
VINx
limit 1500 mA High = activated
0011 I
VINx
limit I
VINx
limit Fast charge current
Low = 100 mA Not applicable Low = ICHG[4:0]
High= 500 mA High = I
VINx
limit 1500 mA High = ICHG[4:0] ÷ 2
0100 I
VINx
limit I
VINx
limit LDO
Low = 100 mA Not applicable Low = LDO active
High= 500 mA High = I
VIN
limit 1500 mA High = LDO disabled
0101 I
VINx
limit I
VINx
limit Charging
Low = 100 mA Not applicable Low = charging disabled
High= 500 mA High = I
VINx
limit 1500 mA High = charging enabled
0110 I
VINx
limit Recharge Charging
Low = 100 mA
Not applicable
Low = charging disabled
High= 500 mA High = disable recharge High = charging enabled
0111 Charging Disable IC1 Recharge
Low = charging disabled Low = not activated Not applicable
High = charging enabled High = activated High = disable recharge
1000 I
VINx
limit I
VINx
limit Interrupt output
Low = 100 mA Not applicable Not applicable
High= 500 mA High = I
VINx
limit 1500 mA Not applicable
1001 I
VINx
limit Charging Interrupt output 1001
Low = 100 mA Low = charging disabled Not applicable ADP5061ACBZ-5-R7
High= 500 mA High = charging enabled Not applicable
1010 I
VINx
limit Disable IC1 Interrupt output
Low = 100 mA Low = not activated Not applicable
High= 500 mA High = activated Not applicable
1011 I
VINx
limit Recharge Interrupt output
Low = 100 mA Not applicable Not applicable
High= 500 mA High = disable recharge Not applicable
1100
I
VINx
limit
Fast charge current
Interrupt output
Low = 100 mA Low = ICHG Not applicable
High= 500 mA High = ICHG[4:0] ÷ 2 Not applicable
1101 I
VINx
limit LDO Interrupt output
Low = 100 mA Low = LDO active Not applicable
High= 500 mA
High = LDO disabled
Not applicable
1110 I
VINx
limit Charging Interrupt output
Not applicable Low = charging disabled Not applicable
High = I
VINx
limit 1500 mA High = charging enabled Not applicable
1111 Disable IC1 Charging Interrupt output
Low = not activated Low = charging disabled Not applicable
High = activated High = charging enabled Not applicable