Rev. C | Page 39 of 44
FACTORY PROGRAMMABLE OPTIONS
CHARGER OPTIONS
Table 38 to Table 50 list the factory programmable options of the ADP5061. In each of these tables, the selection column represents the
default setting of the ADP5061ACBZ-2-R7, ADP5061ACBZ-4-R7, and ADP5061ACBZ-5-R7 models. The difference between these two
models are shown in Table 39, Table 40, Table 42, and Table 50. All other default settings are the same for each model.
Table 38. Default Termination Voltage
Option
Selection
000 = 4.20 V 000 = 4.20 V
010 = 3.70 V
011 = 3.80 V
100 = 3.90 V
101 = 4.00 V
110 = 4.10 V
111 = 4.40 V
Table 39. Default Fast Charge Current
Option Selection/Model
000 = 500 mA
001 = 300 mA 001 = 300 mA/ADP5061ACBZ-5-R7
010 = 550 mA
011 = 600 mA
100 = 750 mA
100 = 750 mA/
ADP5061ACBZ-2-R7, ADP5061ACBZ-4-R7
101 = 900 mA
110 = 1300 mA
111 = 1300 mA
Table 40. Default End of Charge Current
Option Selection/Model
000 = 52.5 mA
000 = 52.5 mA/
ADP5061ACBZ-2-R7, ADP5061ACBZ-4-R77
001 = 72.5 mA
010 = 12.5 mA 010 = 12.5 mA/ADP5061ACBZ-5-R7
011 = 32.5 mA
100 = 142.5 mA
101 = 167.5 mA
110 = 92.5 mA
111 = 117.5 mA
Table 41. Default Trickle to Fast Charge Threshold
Option Selection
00 = 2.5 V 00 = 2.5 V
01 = 2.0 V
10 = 2.9 V
11 = 2.6 V
Table 42. Default System Voltage
Option
Selection/Model
000 = 4.3 V 000 = 4.3 V/ADP5061ACBZ-4-R7
001 = 4.4 V
010 = 4.5 V 010 = 4.5 V/ADP5061ACBZ-5-R7
011 = 4.6 V
100 = 4.7 V
101 = 4.8 V
110 = 4.9 V
111 = 5.0 V 111 = 5.0 V/ADP5061ACBZ-2-R7
Table 43. Thermistor Resistance
Option Selection
0 = 10 kΩ 0 = 10 kΩ
1 = 100 kΩ
Table 44. Thermistor Beta Value
Option Selection
0100 = 3150 0100 = 3150
0101 = 3350
0110 = 3500
0111 = 3650
1000 = 3850
1001 = 4000
1010 = 4200
1011 = 4400
Table 45. DIS_IC1 Mode Select
Option
Selection
0 = DIC_IC1 mode select, VINx current = 280 µA,
ISO_B can float, no leak to ISO_Bx
0
1 = DIC_IC1 mode select, VINx current = 110 µA,
supply switch leaks from VINx to ISO_Bx
Table 46. Trickle or Fast Charge Timer Fault Operation
Option Selection
0 = after timeout LDO off, charging off
1 = after timeout LDO mode active, charging off 1 = LDO mode
active