Rev. C | Page 34 of 44
Table 33. IEND Register, Register Address 0x11
Bit No. Mnemonic Access Default Description
[7:5] IEND[2:0] R/W See Table 40
for the model-
specific default
values.
Termination current programming bus. The values of the termination current can
be programmed to the following values:
000 = 12.5 mA.
001 = 32.5 mA.
010 = 52.5 mA.
011 = 72.5 mA.
100 = 92.5 mA.
101 = 117.5 mA.
110 = 142.5 mA.
111 = 170.0 mA.
4 C/20 EOC R/W 0 The C/20 EOC bit has priority over the other settings (C/10 EOC, C/5 EOC, and IEND).
1 = the termination current is ICHG/20 with the following limitations:
Minimum value = 12.5 mA.
Maximum value = 170 mA.
3 C/10 EOC R/W 0 The C/10 EOC bit has priority over the other termination current settings (IEND),
but does not have priority over the C/20 EOC setting.
1 = the termination current is ICHG/10 unless C/20 EOC is high. The termination
current is limited to the following values:
Minimum value = 12.5 mA.
Maximum value = 170 mA.
2 C/5 EOC R/W 0 The C/5 bit has priority over the other termination current settings (IEND), but
does not have priority over the C/20 EOC setting or the C/10 EOC setting.
1 = the termination current is ICHG / 5 unless the C/20 or the C/10 EOC is high.
The termination current is limited to the following values:
Minimum value = 12.5 mA.
Maximum value = 170 mA.
1:0 SYS_EN_SET[1:0] R/W 00 Selects the operation of the system enable pin (SYS_EN).
00 = SYS_EN is activated when LDO is active and the system voltage is available.
01 = SYS_EN activated by ISO_Bx voltage, the battery charging mode.
10 = SYS_EN is activated and the isolation FET is disabled when the battery drops
below V
WEAK
.
1
11 = SYS_EN is active in LDO mode when the charger is disabled. SYS_EN is active
in the charging mode when V
ISO_B
≥ V
WEAK
.
1
This option is active when VINx = 0 V and the battery monitor is activated from Register 0x07, Bit D5 (EN_BMON).