JEITA Li-Ion Battery Temperature Charging Specification
The ADP5061 is compliant with the JEITA1 and JEITA2 Li-Ion
battery charging temperature specifications as outlined in Table 14
and in Table 16, respectively.
JEITA function can be enabled via the I
2
C interface and,
optionally, the JEITA1 or JEITA2 function can be selected in
I
2
C. Alternatively, the JEITA1 or JEITA2 can be set as enabled
to default by factory programming.
When the ADP5061 identifies a hot or cold battery condition,
the ADP5061 takes the following actions:
• Stops charging the battery.
• Connects or enables the battery isolation FET such that the
ADP5061 continues in LDO mode.
Table 14. JEITA1 Specifications
Parameter Symbol Conditions Min Max Unit
JEITA1 Cold Temperature Limits
I
JEITA_COLD
No battery charging occurs
0
°C
JEITA1 Cool Temperature Limits I
JEITA_COOL
Battery charging occurs at approximately 50% of programmed level—
see Table 15 for specific charging current reduction levels
0 10 °C
JEITA1 Typical Temperature
Limits
I
JEITA_TYP
Normal battery charging occurs at default/programmed levels 10 45 °C
JEITA1 Warm Temperature
Limits
I
JEITA_WARM
Battery termination voltage (V
TRM
) is reduced by 100 mV from
programmed value
45 60 °C
JEITA1 Hot Temperature Limits I
JEITA_HOT
No battery charging occurs 60 °C
Table 15. JEITA1 Reduced Charge Current Levels, Battery Cool Temperature
ICHG[4:0] (Default) ICHG JEITA1 ICHG[4:0] (Default) ICHG JEITA1
00000 = 50 mA 50 mA 01100 = 650 mA 300 mA
00001 = 100 mA 50 mA 01101 = 700 mA 350 mA
00010 = 150 mA 50 mA 01110 = 750 mA 350 mA
00011 = 200 mA 100 mA 01111 = 800 mA 400 mA
00100 = 250 mA 100 mA 10000 = 850 mA 400 mA
00101 = 300 mA 150 mA 10001 = 900 mA 450 mA
00110 = 350 mA 150 mA 10010 = 950 mA 450 mA
00111 = 400 mA 200 mA 10011 = 1000 mA 500 mA
01000 = 450 mA 200 mA 10100 = 1050 mA 500 mA
01001 = 500 mA
250 mA
10101 = 1100 mA
550 mA
01010 = 550 mA 250 mA 10110 = 1200 mA 600 mA
01011 = 600 mA 300 mA 10111 = 1300 mA 650 mA
Table 16. JEITA2 Specifications
Parameter Symbol Conditions Min Max Unit
JEITA2 Cold Temperature
Limits
I
JEITA_COLD
No battery charging occurs 0 °C
JEITA2 Cool Temperature
Limits
I
JEITA_COOL
Battery termination voltage (V
TRM
) is reduced by 100 mV from
programmed value
0 10 °C
JEITA2 Typical Temperature
Limits
I
JEITA_TYP
Normal battery charging occurs at default/programmed levels 10 45 °C
JEITA2 Warm Temperature
Limits
I
JEITA_WARM
Battery termination voltage (V
TRM
) is reduced by 100 mV from
programmed value
45 60 °C
JEITA2 Hot Temperature Limits I
JEITA_HOT
No battery charging occurs 60 °C