Datasheet

ADP5061 Data Sheet
Rev. C | Page 22 of 44
JEITA Li-Ion Battery Temperature Charging Specification
The ADP5061 is compliant with the JEITA1 and JEITA2 Li-Ion
battery charging temperature specifications as outlined in Table 14
and in Table 16, respectively.
JEITA function can be enabled via the I
2
C interface and,
optionally, the JEITA1 or JEITA2 function can be selected in
I
2
C. Alternatively, the JEITA1 or JEITA2 can be set as enabled
to default by factory programming.
When the ADP5061 identifies a hot or cold battery condition,
the ADP5061 takes the following actions:
Stops charging the battery.
Connects or enables the battery isolation FET such that the
ADP5061 continues in LDO mode.
Table 14. JEITA1 Specifications
Parameter Symbol Conditions Min Max Unit
JEITA1 Cold Temperature Limits
I
JEITA_COLD
No battery charging occurs
0
°C
JEITA1 Cool Temperature Limits I
JEITA_COOL
Battery charging occurs at approximately 50% of programmed level
see Table 15 for specific charging current reduction levels
0 10 °C
JEITA1 Typical Temperature
Limits
I
JEITA_TYP
Normal battery charging occurs at default/programmed levels 10 45 °C
JEITA1 Warm Temperature
Limits
I
JEITA_WARM
Battery termination voltage (V
TRM
) is reduced by 100 mV from
programmed value
45 60 °C
JEITA1 Hot Temperature Limits I
JEITA_HOT
No battery charging occurs 60 °C
Table 15. JEITA1 Reduced Charge Current Levels, Battery Cool Temperature
ICHG[4:0] (Default) ICHG JEITA1 ICHG[4:0] (Default) ICHG JEITA1
00000 = 50 mA 50 mA 01100 = 650 mA 300 mA
00001 = 100 mA 50 mA 01101 = 700 mA 350 mA
00010 = 150 mA 50 mA 01110 = 750 mA 350 mA
00011 = 200 mA 100 mA 01111 = 800 mA 400 mA
00100 = 250 mA 100 mA 10000 = 850 mA 400 mA
00101 = 300 mA 150 mA 10001 = 900 mA 450 mA
00110 = 350 mA 150 mA 10010 = 950 mA 450 mA
00111 = 400 mA 200 mA 10011 = 1000 mA 500 mA
01000 = 450 mA 200 mA 10100 = 1050 mA 500 mA
01001 = 500 mA
250 mA
10101 = 1100 mA
550 mA
01010 = 550 mA 250 mA 10110 = 1200 mA 600 mA
01011 = 600 mA 300 mA 10111 = 1300 mA 650 mA
Table 16. JEITA2 Specifications
Parameter Symbol Conditions Min Max Unit
JEITA2 Cold Temperature
Limits
I
JEITA_COLD
No battery charging occurs 0 °C
JEITA2 Cool Temperature
Limits
I
JEITA_COOL
Battery termination voltage (V
TRM
) is reduced by 100 mV from
programmed value
0 10 °C
JEITA2 Typical Temperature
Limits
I
JEITA_TYP
Normal battery charging occurs at default/programmed levels 10 45 °C
JEITA2 Warm Temperature
Limits
I
JEITA_WARM
Battery termination voltage (V
TRM
) is reduced by 100 mV from
programmed value
45 60 °C
JEITA2 Hot Temperature Limits I
JEITA_HOT
No battery charging occurs 60 °C