Datasheet
Data Sheet ADP5052
Rev. 0 | Page 37 of 40
FACTORY DEFAULT OPTIONS
Table 27 lists the factory default options programmed into the ADP5052 when the device is ordered (see the Ordering Guide). To order
the device with options other than the default options, contact your local Analog Devices sales or distribution representative. Table 15
through Table 26 list all available options for the device.
Table 27. Factory Default Options
Option Default Value
Channel 1 output voltage 0.8 V adjustable output
Channel 2 output voltage 0.8 V adjustable output
Channel 3 output voltage 0.8 V adjustable output
Channel 4 output voltage 0.8 V adjustable output
PWRGD pin (Pin 20) output Monitor Channel 1 output
Output discharge function Enabled for all four buck regulators
Switching frequency on Channel 1 1 × switching frequency set by the RT pin
Switching frequency on Channel 3 1 × switching frequency set by the RT pin
SYNC/MODE pin (Pin 43) function Forced PWM/automatic PWM/PSM mode setting with the ability to synchronize to an external clock
Hiccup protection
Enabled for overcurrent events
Short-circuit latch-off function Disabled for output short-circuit events
Overvoltage latch-off function Disabled for output overvoltage events