Datasheet
ADP5050 Data Sheet
Rev. 0 | Page 54 of 60
FACTORY PROGRAMMABLE OPTIONS
Table 51 through Table 64 list the options that can be programmed into the ADP5050 when it is ordered from Analog Devices. For a list
of the default options, see Table 65. To order a device with options other than the default options, contact your local Analog Devices sales
or distribution representative.
Table 51. Output Voltage Options for Channel 1 (Fixed Output Options: 0.85 V to 1.6 V in 25 mV Increments)
Option Description
Option 0 0.8 V adjustable output (default)
Option 1 0.85 V fixed output
Option 2 0.875 V fixed output
… …
Option 30 1.575 V fixed output
Option 31 1.6 V fixed output
Table 52. Output Voltage Options for Channel 2 (Fixed Output Options: 3.3 V to 5.0 V in 300 mV/200 mV Increments)
Option Description
Option 0 0.8 V adjustable output (default)
Option 1 3.3 V fixed output
Option 2 3.6 V fixed output
Option 3 3.9 V fixed output
Option 4 4.2 V fixed output
Option 5 4.5 V fixed output
Option 6 4.8 V fixed output
Option 7 5.0 V fixed output
Table 53. Output Voltage Options for Channel 3 (Fixed Output Options: 1.2 V to 1.8 V in 100 mV Increments)
Option Description
Option 0 0.8 V adjustable output (default)
Option 1 1.2 V fixed output
Option 2 1.3 V fixed output
Option 3 1.4 V fixed output
Option 4 1.5 V fixed output
Option 5
1.6 V fixed output
Option 6 1.7 V fixed output
Option 7 1.8 V fixed output
Table 54. Output Voltage Options for Channel 4 (Fixed Output Options: 2.5 V to 5.5 V in 100 mV Increments)
Option
Description
Option 0 0.8 V adjustable output (default)
Option 1 2.5 V fixed output
Option 2 2.6 V fixed output
… …
Option 30 5.4 V fixed output
Option 31 5.5 V fixed output
Table 55. Pin 20—PWRGD/A0 Pin Options
Option Description
Option 0 PWRGD pin for power-good output (default)
Option 1 A0 pin for I
2
C address setting