REGISTER 7: LCH_CFG (SHORT-CIRCUIT LATCH-OFF
AND OVERVOLTAGE LATCH-OFF CONFIGURATION),
ADDRESS 0x07
Register 7 is used to enable and disable the latch-off function for
short-circuit protection (SCP) and overvoltage protection (OVP).
When the SCP or OVP latch-off function is enabled, the
CHx_LCH bit in Register 12 is set after an error condition
occurs (see the Latch-Off Protection section). The default value
for the SCP latch-off and OVP latch-off functions can be
programmed by factory fuse (SCP or OVP latch-off function
enabled or disabled for all four buck regulators).
Table 31. Register 7 Bit Assignments
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
OVP4_ON OVP3_ON OVP2_ON OVP1_ON SCP4_ON SCP3_ON SCP2_ON SCP1_ON
Table 32. LCH_CFG Register, Bit Function Descriptions
Bits Bit Name Access Description
7 OVP4_ON R/W The default value is programmed by factory fuse.
0 = disable the OVP latch-off function for Channel 4.
1 = enable the OVP latch-off function for Channel 4.
6 OVP3_ON R/W The default value is programmed by factory fuse.
0 = disable the OVP latch-off function for Channel 3.
1 = enable the OVP latch-off function for Channel 3.
5 OVP2_ON R/W The default value is programmed by factory fuse.
0 = disable the OVP latch-off function for Channel 2.
1 = enable the OVP latch-off function for Channel 2.
4 OVP1_ON R/W The default value is programmed by factory fuse.
0 = disable the OVP latch-off function for Channel 1.
1 = enable the OVP latch-off function for Channel 1.
3 SCP4_ON R/W The default value is programmed by factory fuse.
0 = disable the SCP latch-off function for Channel 4.
1 = enable the SCP latch-off function for Channel 4.
2 SCP3_ON R/W The default value is programmed by factory fuse.
0 = disable the SCP latch-off function for Channel 3.
1 = enable the SCP latch-off function for Channel 3.
1 SCP2_ON R/W The default value is programmed by factory fuse.
0 = disable the SCP latch-off function for Channel 2.
1 = enable the SCP latch-off function for Channel 2.
0 SCP1_ON R/W The default value is programmed by factory fuse.
0 = disable the SCP latch-off function for Channel 1.
1 = enable the SCP latch-off function for Channel 1.