Datasheet

Data Sheet ADP5040
Rev. 0 | Page 5 of 40
Parameter Symbol Conditions Min Typ Max Unit
POWER SUPPLY REJECTION
RATIO
PSRR 1 kHz, V
IN2
,
V
IN3
= 3.3 V, V
OUT2
, V
OUT3
= 2.8 V,
I
OUT
= 100 mA
66 dB
100 kHz, V
IN2
,
V
IN3
= 3.3 V, V
OUT2
,
V
OUT3
= 2.8 V,
I
OUT
= 100 mA
57 dB
1 MHz, V
IN2
, V
IN3
= 3.3 V, V
OUT2
,
V
OUT3
= 2.8 V,
I
OUT
= 100 mA
60 dB
1
All limits at temperature extremes are guaranteed via correlation using standard statistical quality control (SQC).
2
This is the input current into V
IN2
and V
IN3
, which is not delivered to the output load.
3
Based on an end-point calculation using 1 mA and 300 mA loads.
4
Dropout voltage is defined as the input-to-output voltage differential when the input voltage is set to the nominal output voltage. This applies only for output
voltages above 1.7 V.
5
Current-limit threshold is defined as the current at which the output voltage drops to 90% of the specified typical value. For example, the current limit for a 3.0 V
output voltage is defined as the current that causes the output voltage to drop to 90% of 3.0 V, or 2.7 V.
INPUT AND OUTPUT CAPACITOR, RECOMMENDED SPECIFICATIONS
Table 4.
Parameter Symbol Conditions Min Typ Max Unit
INPUT CAPACITANCE (BUCK)
1
C
MIN1
T
J
= −40°C to +125°C 4.7 40 µF
OUTPUT CAPACITANCE (BUCK)
2
C
MIN2
T
J
= −40°C to +125°C 7 40 µF
INPUT AND OUTPUT CAPACITANCE
3
(LDO1, LDO2) C
MIN34
T
J
= −40°C to +125°C 0.70 µF
CAPACITOR ESR R
ESR
T
J
= −40°C to +125°C 0.001 1 Ω
1
The minimum input capacitance should be greater than 4.7 µF over the full range of operating conditions. The full range of operating conditions in the application
must be considered during device selection to ensure that the minimum capacitance specification is met. X7R and X5R type capacitors are recommended, whereas
Y5V and Z5U capacitors are not recommended for use with the buck.
2
The minimum output capacitance should be greater than 7 µF over the full range of operating conditions. The full range of operating conditions in the application
must be considered during device selection to ensure that the minimum capacitance specification is met. X7R and X5R type capacitors are recommended, whereas
Y5V and Z5U capacitors are not recommended for use with the buck.
3
The minimum input and output capacitance should be greater than 0.70 µF over the full range of operating conditions. The full range of operating conditions in the
application must be considered during device selection to ensure that the minimum capacitance specification is met. X7R and X5R type capacitors are recommended,
whereas Y5V and Z5U capacitors are not recommended for use with LDOs.