Datasheet
ADP199 Data Sheet
Rev. A | Page 4 of 16
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter Rating
VIN to GND −0.3 V to +4.0 V
VOUT to GND −0.3 V to V
IN
EN to GND −0.3 V to +4.0 V
Continuous Drain Current
T
A
= 25°C ±1000 mA
T
A
= 85°C ±700 mA
Continuous Diode Current −50 mA
Storage Temperature Range
−65°C to +150°C
Operating Junction Temperature Range −40°C to +85°C
Soldering Conditions JEDEC J-STD-020
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 3. Typical θ
JA
and Ψ
JB
Values
Package Type θ
JA
Ψ
JB
Unit
4-Ball, 0.4 mm Pitch WLCSP 260 58 °C/W
ESD CAUTION