Datasheet

EVAL-ADP190
Rev. 0 | Page 6 of 8
SHUTDOWN CURRENT MEASUREMENT
Figure 8 shows how the evaluation board can be connected to a
voltage source and an ammeter for shutdown current measure-
ments. The ammeter can also be connected to the GND terminal
to measure the ground current, which is equal to the shutdown
current when EN is tied to ground. Figure 7 shows the typical
shutdown current consumption for various input voltages.
07862-007
0.7
0.6
0.5
0.4
0.3
0.2
0
0.1
1251007550250–25–50
JUNCTION TEMPERATURE, T
J
C)
SHUTDOWN CURRENT (µA)
V
IN
= 1.2V
V
IN
= 1.8V
V
IN
= 2.5V
V
IN
= 3.6V
Figure 7. Shutdown Current vs. Temperature and Input Voltage
Follow these steps to connect to a voltage source and ammeter:
1. Connect the positive terminal (+) of the voltage source to
the (+) of the ammeter.
2. Connect the negative (−) terminal of the voltage source to
GND pad on the evaluation board.
3. Connect the negative terminal () of the ammeter to the
VIN pad on the evaluation board.
4. Connect the EN pin to ground using Jumper J1.
The voltage source can now be turned on.
VOLTAGE SOURCE
VIN
AMMETER
GND CURRENT
0.035
07862-008
J1
Figure 8. Shutdown Current Measurement