REGISTER MAP
The highest bit number (7) represents the most significant bit; the lowest bit number (0) represents the least significant bit.
Table 11. Register Map
Address Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0x00 Design information DEVICE_ID REV_ID
0x01 Output mode IL_PEAK STR_LV STR_MOD STR_POL LED_MOD
0x02 GPIO and timer LED_SD TEST_SR IO_CFG FL_TIM
0x03 Additional features CL_SOFT DYN_OVP SW_LO FREQ_FB IL_DC IL_DC_EN
0x04 Low battery mode enable Reserved V_BATT_WINDOW V_VB_LO
0x05 Low battery mode current Reserved I_VB_LO
0x06 LED1 flash current Reserved I_FL1
0x07 LED1 TxMASK current Reserved I_TX1
0x08 LED1 torch/assist current Reserved I_TOR1
0x09 LED2 flash current Reserved I_FL2
0x0A LED2 TxMASK current Reserved I_TX2
0x0B LED2 torch/assist current Reserved I_TOR2
0x0C Fault information FL_OVP FL_SC FL_OT FL_TO FL_TX FL_VB_LO FL_IL FL_IDC
0x0D LED1 flash current fault
readback
Reserved FL_I_FL1
0x0E LED2 flash current fault
readback
Reserved FL_I_FL2
0x0F LED enable mode Reserved LED2_EN LED1_EN
REGISTER DETAILS
Table 12. Design Information Register (Register 0x00)
Bits Bit Name Access Description
[7:3] DEVICE_ID R Device ID for the ADP1660 (00011).
[2:0] REV_ID R Revision ID.
Table 13. Output Mode Register (Register 0x01)
Bits Bit Name Access Description
[7:6] IL_PEAK R/W These bits set the inductor peak current limit.
00 = 2.25 A.
01 = 2.75 A.
10 = 3.25 A (default).
11 = 3.5 A.
5 STR_LV R/W This bit sets the sensitivity for the STROBE pin.
0 = edge sensitive.
1 = level sensitive (default).
4 STR_MOD R/W This bit sets the strobe mode.
0 = software strobe mode; software flash occurs when the output is enabled in flash mode.
1 = hardware strobe mode; the STROBE pin must go high for flash (default).
3 STR_POL R/W This bit sets the polarity of the STROBE pin.
0 = active low.
1 = active high (default).
[2:0] LED_MOD R/W These bits set the LED output mode.
000 = standby mode (default).
001 = fixed 5 V output mode.
010 = assist light mode.
011 = flash mode.
100 = independent trigger mode with timeout enabled.
101 = independent trigger mode with timeout disabled.
110 = fixed 5 V output mode with torch mode (total output current must be below 500 mA).
111 = reserved.