Datasheet
Table Of Contents

ADP1614 Data Sheet
Rev. A | Page 4 of 20
Parameter Symbol Test Conditions/Comments Min Typ Max Unit
THERMAL SHUTDOWN
Thermal Shutdown Threshold 150 °C
Thermal Shutdown Hysteresis 20 °C
1
This parameter specifies the average current when the device switches internally with the SW pins (Pin 6 and Pin 7) grounded.
2
Guaranteed by design.
3
Current limit is a function of duty cycle. For the adjustable current limit versions, it is also a function of the resistor on the CLRES pin. See Figure 10 through Figure 13.
4
The CLRES pin cannot be controlled with a current source. An equivalent resistance should be used.