Datasheet

Evaluation Board User Guide UG-320
Rev. A | Page 45 of 48
Register Address Programmed Setting Name
0x32 0x5A VS1 overvoltage limit
0x33 0x0B VS3 overvoltage limit
0x34 0x28 VS1 undervoltage limit
0x35 0xFF Line impedance limit
0x36
0x07
Load line impedance
0x37 0xDD Fast OVP comparator settings
0x38 0x00 VS1 trim
0x39 0x00 VS2 trim
0x3A 0x00 VS3 trim
0x3B 0x45 Light load disable setting
0x3C 0x00 Silicon revision ID
0x3D 0x00 Manufacturer ID
0x3E 0x00 Device ID
0x3F 0x9B OUTAUX switching frequency setting
0x40 0x1B PWM switching frequency setting
0x41 0x00 PWM1 positive edge timing
0x42 0x01 PWM1 positive edge setting
0x43 0x00 PWM1 negative edge timing
0x44 0x18 PWM1 negative edge setting
0x45 0x00 PWM2 positive edge timing
0x46 0x00 PWM2 positive edge setting
0x47
0x00
PWM2 negative edge timing
0x48 0x18 PWM2 negative edge setting
0x49 0x02 PWM3 positive edge timing
0x4A 0x88 PWM3 positive edge setting
0x4B 0x51 PWM3 negative edge timing
0x4C 0xC0 PWM3 negative edge setting
0x4D 0x2A PWM4 positive edge timing
0x4E 0x10 PWM4 positive edge setting
0x4F 0x2A PWM4 negative edge timing
0x50 0x18 PWM4 negative edge setting
0x51 0x2A SR1 positive edge timing
0x52
0x00
SR1 positive edge setting
0x53 0x2A SR1 negative edge timing
0x54 0x18 SR1 falling edge setting
0x55 0x2C SR2 rising edge Timing
0x56 0x88 SR2 rising edge setting
0x57 0x27 SR2 falling edge timing
0x58 0x80 SR2 falling edge setting
0x59 0x00 PWM OUTAUX rising edge timing
0x5A 0x00 PWM OUTAUX rising edge setting
0x5B 0x0A PWM OUTAUX falling edge timing
0x5C 0x08 PWM OUTAUX falling edge setting
0x5D 0x00 PWM and SRx pin disable setting
0x5E 0x7F ACSNS gain trim
0x5F 0xD2 Soft start and output voltage slew rate setting
0x60 0x22 Normal mode digital filter LF gain setting
0x61 0xF2 Normal mode digital filter zero setting
0x62 0xCA Normal mode digital filter pole setting
0x63
0x3D
Normal mode digital filter HF gain setting
0x64 0x22 Light load digital filter LF gain setting
0x65 0xF2 Light load digital filter zero setting
0x66 0xCA Light load digital filter pole setting