Datasheet

Evaluation Board User Guide UG-320
Rev. A | Page 11 of 48
8. The original register configuration is stored in the
ADP1046_I2SF_B_xxxx.46r register file. (Note that all
register files have an extension of .46r.) The file can be
loaded using the second icon from the left in Figure 10.
The IC on the board is preprogrammed, and this step is
optional.
9. Connect a dc power source (385 V dc nominal, current
limit to ~1 A) and an electronic load set to 1 A at the output.
10. Connect a voltmeter at the TP37 and TP38 test points.
Ensure that the differential probes are used and that the
ground of the probes are isolated if oscilloscope
measurements are made on the primary side of the
transformer.
11. Turn the PSON switch (SW1 on schematic; see Figure 76)
to the on position. Then click the dashboard settings icon
(2
nd
icon from the left in Figure 8), and turn on the
software via PSON.
The board should now be operational and ready for
evaluation. The output should read 12 V dc.
12. Click the Monitor tab and then the Flags and Readings
button (not shown) to load the entire state of the power
supply unit (PSU) in a single user-friendly window (see
Figure 11).
13. After successful startup and the board is in a steady state
condition, LEDs on the board provide the status of the board.
All the LEDs turn on, indicating that there are no faults
detected, such as overvoltage or overcurrent. In case of a
fault, the PGOOD1 or PGOOD2 LED turns off, indicating
that a flag has tripped due to an out of bounds condition.
The Flags and Readings window displays the appropriate
state of the PSU.
Table 4. List of LEDs on the Evaluation Board
LED
Description
D23 (Red)
PGOOD1 signal (active low)
D24 (Red)
PGOOD2 signal (active low)
D15 (Red) Indicates OrFET is turned on
D12 (White)
12 V from auxiliary boost
BOARD SETTINGS
The board settings can be accessed from the main setup
window (see Figure 9).
10180-008
Figure 10. Different Icons on Dashboard for Loading and Saving .46r and .46b Files