Datasheet
ADN2848 Data Sheet
Rev. B | Page 4 of 12
Parameter Min Typ Max Unit Conditions/Comments
SUPPLY
I
CC
5
50 mA I
BIAS
= I
MOD
= 0
V
CC
6
3.0 3.3 3.6 V
1
Temperature range is −40°C to +85°C.
2
Measured into a 25 Ω load using a 0-1 pattern at 622 Mbps.
3
When the voltage on DATAP is greater than the voltage on DATAN, the modulation current flows in the IMODP pin.
4
Guaranteed by design and characterization. Not production tested.
5
I
CCMIN
for power calculation on Page 9 is the typical I
CC
given.
6
All V
CC
pins should be shorted together.
t
S
t
H
SETUP
HOLD
DATAP/DATAN
CLKP
02746-002
Figure 2. Setup and Hold Time