Datasheet
ADM706P/ADM706R/ADM706S/ADM706T, ADM708R/ADM708S/ADM708T
Rev. C | Page 4 of 16
Parameter Min Typ Max Unit Test Conditions/Comments
MANUAL RESET INPUT
MR Pull-Up Current (MR = 0 V)
25 70 250 μA V
RST
(max) < V
CC
< 3.6 V
100 250 600 μA 4.5 V < V
CC
< 5.5 V
MR Pulse Width
500 ns V
RST
(max) < V
CC
< 3.6 V
150 ns 4.5 V < V
CC
< 5.5 V
MR INPUT THRESHOLD
V
IL
0.6 V V
RST
(max) < V
CC
< 3.6 V
V
IH
0.7 × V
CC
V V
RST
(max) < V
CC
< 3.6 V
V
IL
0.8 V 4.5 V < V
CC
< 5.5 V
V
IH
2.0 V 4.5 V < V
CC
< 5.5 V
MR TO RESET OUTPUT DELAY
750 ns V
RST
(max) < V
CC
< 3.6 V
250 ns 4.5 V < V
CC
< 5.5 V
POWER-FAIL INPUT
PFI Input Threshold 1.2 1.25 1.3 V
ADM70xP/ADM70xR, V
CC
= 3 V
ADM70xS/ADM70xT, V
CC
= 3.3 V, PFI falling
PFI Input Current −25 +0.01 +25 nA
PFO OUTPUT VOLTAGE
V
OH
0.8 × V
CC
V V
RST
(max) < V
CC
< 3.6 V, I
SOURCE
= 500 μA
V
OL
0.3 V V
RST
(max) < V
CC
< 3.6 V, I
SINK
= 1.2 mA
V
OH
V
CC
− 1.5 V V 4.5 V < V
CC
< 5.5 V, I
SOURCE
= 800 μA
V
OL
0.4 V 4.5 V < V
CC
< 5.5 V, I
SINK
= 3.2 mA