Datasheet
Data Sheet ADM3307E/ADM3310E/ADM3311E/ADM3312E/ADM3315E
Rev. I | Page 17 of 24
R1
C1
ESD TEST METHOD R2 C1
IEC1000-4-2
1.5kV 100pF
HUMAN BODY MODEL
ESD ASSOC. STD 55.1
330V 150pF
DEVICE
UNDER TEST
HIGH
VOLTAGE
GENERATOR
R2
02915-034
Figure 34. ESD Test Standards
100
90
36.8
10
TIME
t
t
DL
t
RL
I
PEAK
(%)
0
2915-035
Figure 35. Human Body Model ESD Current Waveform
100
90
10
TIME
t
30ns
60ns
0.1ns TO 1ns
I
PEAK
(%)
02915-036
Figure 36. IEC1000-4-2 ESD Current Waveform
The ADM33xxE devices are tested using both of the previously
mentioned test methods. All pins are tested with respect to all
other pins as per the Human Body Model, ESD Assoc. Std. 55.1
specification. In addition, all I/O pins are tested as per the IEC
1000-4-2 test specification. The products were tested under the
following conditions:
Power-On—Normal Operation
Power-Off
There are four levels of compliance defined by IEC 1000-4-2.
The ADM33xxE parts meet the most stringent compliance level
for both contact and air-gap discharge. This means the products
are able to withstand contact discharges in excess of 8 kV and
airgap discharges in excess of 15 kV.
Table 9. IEC 1000-4-2 Compliance Levels
Level Contact Discharge (kV) Air Discharge (kV)
1 2 2
2 4 4
3 6 8
4 8 15