Datasheet
Table Of Contents
Data Sheet ADM3053
Rev. E | Page 7 of 18
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted. All voltages are relative to
their respective ground.
Table 6.
Parameter Rating
V
CC
−0.5 V to +6 V
V
IO
−0.5 V to +6 V
Digital Input Voltage, TxD −0.5 V to V
IO
+ 0.5 V
Digital Output Voltage, RxD −0.5 V to V
IO
+ 0.5 V
CANH, CANL −36 V to +36 V
V
REF
−0.5 V to +6 V
R
S
−0.5 V to +6 V
Operating Temperature Range −40°C to +85°C
Storage Temperature Range −55°C to +150°C
ESD (Human Body Model)
3 kV
Lead Temperature
Soldering (10 sec) 300°C
Vapor Phase (60 sec)
215°C
Infrared (15 sec) 220°C
θ
JA
Thermal Impedance 53°C/W
T
J
Junction Temperature 150°C
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Table 7. Maximum Continuous Working Voltage
1
Parameter Max Unit Reference Standard
AC Voltage
Bipolar Waveform
424
V peak
50 year minimum
lifetime
Unipolar Waveform
Basic Insulation 1074 V peak
Maximum approved
working voltage per
IEC60950-1
Reinforced Insulation
537
V peak
Maximum approved
working voltage per
IEC60950-1
DC Voltage
Basic Insulation 1074 V peak
Maximum approved
working voltage per
IEC60950-1
Reinforced Insulation 537 V peak
Maximum approved
working voltage per
IEC60950-1
1
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
ESD CAUTION