REGULATORY INFORMATION
Table 5. ADM2682E/ADM2687E Approvals
Organization Approval Type
UL
To be recognized under the UL 1577 Component Recognition Program of Underwriters Laboratories, Inc.
Single protection, 5000 V rms isolation voltage.
In accordance with UL 1577, each ADM2682E/ADM2687E is proof tested by applying an insulation test voltage
6000 V rms for 1 second.
CSA (Pending)
To be approved under CSA Component Acceptance Notice #5A.
Reinforced insulation per IEC 60601-1, 250 V rms (353 V peak) maximum working voltage.
Basic insulation per IEC 60601-1, 400 V rms (566 V peak) maximum working voltage.
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1, 380 V rms (537 V peak) maximum working voltage.
Basic insulation per CSA 60950-1-07 and IEC 60950-1, 600 V rms (848 V peak) maximum working voltage.
VDE
Certified according to DIN V VDE V 0884-10 (VDE 0884-10): 2006-12.
In accordance with DIN EN 60747-5-2, each ADM2682E/ADM2687E is proof tested by applying an insulation test voltage
≥1590 V peak for 1 second.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) >8.0 mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) >8.0 mm Measured from input terminals to output terminals,
shortest distance along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303-1
Isolation Group IIIa Material Group (DIN VDE 0110:1989-01, Table 1)