ADM1276 Data Sheet
Rev. C | Page 36 of 48
OPERATION
Code: 0x01, read/write byte. Value after reset: 0x80.
Table 10. Bit Descriptions for OPERATION Command
Bits Bit Name Settings Description
[7] On 0 Hot swap output is disabled.
1 Default. Hot swap output is enabled.
[6:0]
Reserved
0000000
Always reads as 0000000.
CLEAR_FAULTS
Code: 0x03, send byte, no data.
CAPABILITY
Code: 0x19, read byte. Value after reset: 0xB0.
Table 11. Bit Descriptions for CAPABILITY Command
Bits Bit Name Settings Description
[7] Packet error checking 1 Always reads as 1. Packet error checking (PEC) is supported.
[6:5] Maximum bus speed 01 Always reads as 01. Maximum supported bus speed is 400 kHz.
[4]
SMBALERT#
1
Always reads as 1. Device supports SMBAlert and alert response address (ARA).
[3:0] Reserved 0000 Always reads as 0000.
VOUT_OV_WARN_LIMIT
Code: 0x42, read/write word. Value after reset: 0x0FFF.
Table 12. Bit Descriptions for VOUT_OV_WARN_LIMIT Command
Bits Bit Name Settings Description
[15:12] Reserved 0000 Always reads as 0000.
[11:0] VOUT_OV_WARN_LIMIT Overvoltage threshold for the VOUT pin measurement, expressed in ADC codes.
VOUT_UV_WARN_LIMIT
Code: 0x43, read/write word. Value after reset: 0x0000.
Table 13. Bit Descriptions for VOUT_UV_WARN_LIMIT Command
Bits Bit Name Settings Description
[15:12]
Reserved
0000
Always reads as 0000.
[11:0] VOUT_UV_WARN_LIMIT Undervoltage threshold for the VOUT pin measurement, expressed in ADC codes.
IOUT_OC_WARN_LIMIT
Code: 0x4A, read/write word. Value after reset: 0x0FFF.
Table 14. Bit Descriptions for IOUT_OC_WARN_LIMIT Command
Bits Bit Name Settings Description
[15:12] Reserved 0000 Always reads as 0000.
[11:0] IOUT_OC_WARN_LIMIT
Overcurrent threshold for the IOUT measurement through the sense resistor,
expressed in ADC codes.
IOUT_WARN2_LIMIT
Code: 0xD7, read/write word. Value after reset: 0x0000.
Table 15. Bit Descriptions for IOUT_WARN2_LIMIT Command
Bits Bit Name Settings Description
[15:12] Reserved 0000 Always reads as 0000.
[11:0]
IOUT_WARN2_LIMIT
Threshold for the IOUT measurement through the sense resistor, expressed in ADC
codes. This value can be either an undercurrent or an overcurrent, depending on the
state of the IOUT_WARN2_SELECT bit that is set using the DEVICE_CONFIG command.