Datasheet

ADM1064
Rev. D | Page 6 of 32
Parameter Min Typ Max Unit Test Conditions/Comments
Data Setup Time, t
SU;DAT
100 ns
Data Hold Time, t
HD;DAT
5 ns
Input Low Current, I
IL
1 μA V
IN
= 0 V
SEQUENCING ENGINE TIMING
State Change Time 10 μs
1
At least one of the VH, VPx pins must be ≥3.0 V to maintain the device supply on VDDCAP.
2
Specification is not production tested but is supported by characterization data at initial product release.
3
Timing specifications are guaranteed by design and supported by characterization data.