Datasheet

ADG918/ADG919 Data Sheet
Rev. D | Page 4 of 16
B Version
Parameter Symbol Test Conditions/Comments Min Typ
1
Max Unit
CAPACITANCE
3
RF On Capacitance C
RF
ON f = 1 MHz 1.6 pF
CTRL Input Capacitance C
CTRL
f = 1 MHz 2 pF
POWER REQUIREMENTS
V
DD
1.65 2.75 V
Quiescent Power Supply Current I
DD
Digital inputs = 0 V or V
DD
0.1 1 µA
1
Typical values are at V
DD
= 2.5 V and 25°C, unless otherwise stated.
2
Point at which insertion loss degrades by 1 dB.
3
Guaranteed by design, not subject to production test.
4
The dc transience at the output of any port of the switch when the control voltage is switched from high to low or low to high in a 50 Ω test setup, measured with 1 ns
rise time pulses and 500 MHz bandwidth.