Datasheet
REV. A
–6–
50
45
0
25
15
10
5
40
30
20
35
V
D
(V
S
) – Volts
V
DD
= +3V
V
SS
= –3V
V
DD
= +5V
V
SS
= –5V
ON RESISTANCE – Ω
–5.0 5.0–4.0 0.0 3.0 4.0–3.0 –2.0 –1.0 1.0 2.0
T
A
= +25
o
C
Figure 1. R
ON
as a Function of V
D
(V
S
): Dual Supply Voltage
50
ON RESISTANCE – Ω
45
0
–5.0 5.0–4.0 0.0 3.0 4.0
25
15
10
5
40
30
20
35
–3.0 –2.0 –1.0 1.0 2.0
V
D
(V
S
) – Volts
V
DD
= +5V
V
SS
= –5V
+125
o
C
+85
o
C
+25
o
C
Figure 2. R
ON
as a Function of V
D
(V
S
) for Different
Temperatures
100
ON RESISTANCE – Ω
90
0
0.0 3.00.5 1.5
50
30
20
10
80
60
40
70
1.0 2.52.0
V
DD
= +3V
V
SS
= 0V
+125
o
C
+85
o
C
+25
o
C
V
D
(V
S
) – Volts
Figure 3. R
ON
as a Function of V
D
(V
S
) for Different
Temperatures
ADG608/ADG609–Typical Performance Characteristics
100
ON RESISTANCE – Ω
90
0
0.0 5.00.5 2.5 4.0 4.5
50
30
20
10
80
60
40
70
1.0 1.5 2.0 3.0 3.5
V
D
(V
S
) – Volts
V
DD
= +3V
V
SS
= 0V
V
DD
= +5V
V
SS
= 0V
T
A
= +25
o
C
Figure 4. R
ON
as a Function of V
D
(V
S
): Single Supply Voltage
100
ON RESISTANCE – Ω
90
0
0.0 5.00.5 2.5 4.0 4.5
50
30
20
10
80
60
40
70
1.0 1.5 2.0 3.0 3.5
V
D
(V
S
) – Volts
V
DD
= +5V
V
SS
= 0V
+125
o
C
+85
o
C
+25
o
C
Figure 5. R
ON
as a Function of V
D
(V
S
) for Different
Temperatures
V
S
, V
D
– Volts
0.03
0.00
–0.03
–5 5–4
LEAKAGE CURRENTS – nA
–3 –2 –1 0 1 2 3 4
0.02
0.01
–0.01
–0.02
I
D
(OFF)
I
D
(ON)
I
S
(OFF)
V
DD
= +5V
V
SS
= –5V
T
A
= +25
o
C
Figure 6. Leakage Currents as a Function of V
D
(V
S
)